Cal. Code Regs. tit. 8, § 3083
(b) Where the transfer of load is in a nonrestricted area, there shall be a clearance of not less than 4 feet between the end of the transferred load and any fixed obstruction in line with the end of the load.
Exception: A clearance of not less than 2 feet will be allowed where the system is arranged to prevent the automatic transfer of more than one load into the area.
(c) In nonrestricted areas, discharge shall not take place unless the area is clear or a protective device or suitable guarding is provided. Guarding means shall be: