Cal. Code Regs. tit. 8, § 1908
(b) No passenger shall be transported in the helicopter with a sling load and no person shall be transported as an external or sling load, except in an emergency.
Exception: Unless authorized by the F.A.A.
(g) When stringing lines or conductors close to or parallel to energized lines, conductive lines or reels, pay-out machines, and conductors shall be grounded as required by the High Voltage Electrical Safety Orders. Hoist wires or other gear shall not be attached to any fixed ground structure.
Exception: When pulling lines or conductors that are allowed to “pay-out” from a container or roll off a reel.
(j) There shall be a minimum clearance of at least 25 feet between any energized power line, rated 50 KV or below, and any part of the rotorcraft load combination. This clearance requirement shall increase at the rate of ½ inch for each 1 KV.
Exception: These minimum clearances shall not apply to helicopters or their external loads specifically utilized for power line construction, maintenance, and repair where the work in progress is under the direct supervision of the utility.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. Amendment filed 2-1-85; effective thirtieth day thereafter (Register 85, No. 5).