- (a) Concrete Mixers. Concrete mixers equipped with 1-yard, or larger, loading skips shall be provided with a device to clear the skip of material. Skip clearing shall not be done by a worker standing under or near a raised skip while striking it with a hand-held implement.
- (b) On concrete mixers of 1 yard capacity, or larger, guardrails of pipe or similar material shall be provided on each side of the dangerous area under the raised skip.
- (c) Bull float handles, which could come in contact with energized electrical conductors, shall be constructed of nonconductive material.
- (d) Concrete troweling machines--of the powered, rotating-blade type--that are guided manually shall be equipped with a control or switch that will automatically shut off the power whenever the operator's hands are removed from the equipment handles.
(e) Mortar, Plaster or Fireproofing Mixers.
- (1) Grid guards on mortar, plaster or fireproofing mixers of 1 yard capacity or smaller shall have a grid opening not to exceed 16 square inches with a minimum clearance of 5 inches from the top of the grid guard to the top of the mixing paddles.
- (2) All mortar, plaster or fireproofing mixers of 1 yard capacity or smaller ordered or purchased after the effective date of this regulation shall be equipped with grid guards with an opening not to exceed 16 square inches with a minimum clearance of 5 inches from the top of the grid guard to the top of the mixing paddles.
- (f) Tremies. Sections of tremies and similar concrete conveyances shall be secured with wire rope in addition to the regular couplings or connections.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
History
1. Amendment of subsection (d) and new subsection (e) filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 35).
2. New subsection (f) filed 10-22-90; operative 11-21-90 (Register 90, No. 48).
3. Change without regulatory effect amending subsection (b) filed 6-22-98 pursuant to section 100, title 1, California Code of Regulations (Register 98, No. 26).
4. Repealer and new subsection (c) filed 10-21-99; operative 11-20-99 (Register 99, No. 43).
5. Amendment of subsections (e)(1) and (e)(2) filed 10-23-2001; operative 11-22-2001 (Register 2001, No. 43).