- (a) When portable compressors on wheels stand unattached to other equipment, they shall be positively locked, blocked, or otherwise adequately prevented from rolling.
- (b) Fans shall be guarded with a shroud or side screens.
- (c) Compressed air tanks shall be drained of liquid as recommended by the manufacturer's specifications.
- (d) Compressor safety valves shall be popped at least weekly.
- (e) Compressed air tanks shall comply with all applicable safety orders of Article 3 of the Unfired Pressure Vessel Safety Orders, Title 8, California Code of Regulations, applying to tank design, safety devices and operating permits.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
History
1. Amendment of subsection (e) filed 10-18-77; effective thirtieth day thereafter (Register 77, No. 43).
2. Amendment of subsection (c) filed 1-13-87; effective thirtieth day thereafter (Register 87, No. 4).
3. Change without regulatory effect amending subsection (e) filed 10-29-97 pursuant to section 100, title 1, California Code of Regulations (Register 97, No. 44).