Cal. Code Regs. tit. 8, § 8497
(a) Factor of Safety. All rope to be used for regular hoisting shall be wire rope providing a factor of safety not less than five to one for material hoist and ten to one for personnel hoist when new, which shall be calculated by dividing the breaking strength of the wire rope as given in the manufacturer's published tables, by the total load to be hoisted including the total weight of the wire rope in the shaft when fully let out, plus a proper allowance for impact and acceleration.
The acceleration allowance shall be in accordance with manufacturer's recommendations, but in all cases the factor of safety of five or more must be maintained when the load, used in determining it, is greater than the actual weight by a percentage that is numerically three times the acceleration or deceleration, whichever is greatest. For example, a deceleration or acceleration of two feet per second that increases the load would require use of an effective load 6 percent greater than the actual weight, in the calculation of a factor of safety.
(b) Wire Rope Fastenings. Every wire rope used for hoisting shall be securely fastened at both ends and when in use shall not be fully unwound; at least three full turns shall remain on the drum so as to protect the end fastening at drum from overload. The wire rope end at the cage, skip or bucket shall be securely fastened by a properly made tapered socket joint, by an eye in the wire rope made with an oval thimble and wire rope clips, or by another method acceptable to the Division for this or similar service. If the wire rope clip method is used, the spacing and number used shall be as shown in Table - 1 for U-Bolts and in Table - 2 for Fist-Grip clips based upon using RRL or RLL wire rope, 6 x 19 or 6 x 37 Class, FC or IWRC; IPS or XIP. If Seale construction or similar large outer wire type construction in the 6 x 19 Class is to be used for sizes 1 inch and larger, add one additional clip. If a pulley (sheave) is used for turning back the wire rope, add one additional clip.
The number of clips shown also applies to rotation-resistant RRL wire rope, 8 x 19 Class, IPS, XIP, sizes 1- ½ inch and smaller; and to rotation-resistant RRL wire rope, 19 x 7 Class, IPS, XIP (sizes 1- ¾ inch and smaller for U-Bolts and size 1- ½ inch and smaller for Fist Grips).
Note: Wire rope abbreviation used above --
RRL
--
Right Regular Lay
Rll
--
Right Lange Lay
FC
--
Fiber Rope Core
IWRC
--
Independent Wire Rope Core
IPS
--
Improved Plow Steel
XIP
--
Extra Improved Plow Steel
Table 1 - Manufacturer's Recommendation for Using U-Bolt with Thimble Terminations
Clip Size* Inches
Min. No. of Clips
Amount of Rope to Turn Back -- Inches
Torque in Lbs. Ft.
½
3
11- ½
65
9/16
3
12
95
⅝
3
12
95
¾
4
18
130
⅞
4
19
225
1
5
26
225
1- ⅛
6
34
225
1- ¼
6
37
360
1- ⅜
7
44
360
1- ½
7
48
360
1- ⅝
7
51
430
1/34
7
53
590
2
8
71
750
2- ¼
8
73
750
* Same as nominal rope diameter.
If a greater number of clips used than shown in the table, the amount of rope turnback should be increased proportionately. ABOVE BASED ON USE OF CLIPS ON NEW ROPE.
Manufacturer's recommendations shall be followed for other kinds of wire ropes.
Table 2 - Manufacturer's Recommendation for Using Fist Clips with Thimble Terminations.
Clip Size* Inches
Min. No. of Clips
Amount of Rope to Turn Back -- Inches
Torque in Lbs. Ft.
½
3
11
65
9/16
3
12- ¾
130
⅝
3
13- ½
130
¾
4
16
225
⅞
4
26
225
1
5
37
225
1- ⅛
5
41
360
1- ¼
6
55
360
1- ⅜
6
62
500
1- ½
7
78
500
If a greater number of clips are used than shown in the table, the amount of turnback should be increased proportionately.
* The tightening torque values shown are based upon the threads being clean, dry, and free of lubrication.
(c) Unsafe Wire Rope. No wire rope shall be used for hoisting when:
(e) Sheave and Drum Diameters. Each head sheave and hoist drum shall have a minimum diameter, according to the type of wire rope used, as follows:
6 x 7 wire rope
--
42 times rope diameter
6 x 19 wire rope
--
30 times rope diameter
6 x 37 wire rope
--
18 times rope diameter
8 x 19 wire rope
--
21 times rope diameter
(f) End Connections.
Note: Authority cited: Sections 142.3 and 7997, Labor Code. Reference: Sections 142.3 and 7997, Labor Code.
1. Renumbering and amendment of former section 8497 to section 8494 and new section heading, section and Note filed 3-5-96; operative 4-4-96 (Register 96, No. 10).
2. Editorial correction of subsection (g) (Register 2013, No. 16).
3. Amendment of subsection (a) filed 1-9-2014; operative 4-1-2014 (Register 2014, No. 2).