Cal. Code Regs. tit. 8, § 6595
(a) A platform at least twenty-four inches (24″) wide shall be provided completely across each outer side of the derrick or mast adjacent to and level with the ends of the pipe-racking support. The outer edges of these platforms shall be equipped with standard railings and toeboards. If the design of a derrick or mast is such as to make outside platforms impractical, then inside platforms at least twenty-four inches (24″) wide and adjacent to and level with the ends of the pipe-racking support may be used.
Exception: On cantilever derricks and masts equipped with an adjustable pipe-racking support, the outside platform may be not more than thirty inches (30″) below or twenty-four inches (24″) above the pipe-racking support provided that railing extensions are installed for safe access between the outside platform and pipe-racking support.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. Amendment filed 7-20-59; effective thirtieth day thereafter (Register 59, No. 12).
2. Amendment of section heading, section and Note filed 5-8-95; operative 6-7-95 (Register 95, No. 19).