- (a) Name of manufacturer, city and state where manufactured.
- (b) Model number.
- (c) Maximum size of mainline for which the spar is designed.
- (d) Number and size of guylines and any other lines required.
- (e) Maximum size of skyline, mainline, and haulback line that can be used if the spar is designed for a skyline, slackline, or modified slackline system.
- (f) Maximum and minimum inclination at which the spar is designed to be operated.
Each portable metal spar shall have identification and specification plates permanently attached to its base, in a position that can be easily read by a person standing on the ground or on the base platform. Plates shall contain the following information:
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.