Cal. Code Regs. tit. 8, § 506
(a) Tanks or cylinders used to furnish anhydrous ammonia to agricultural applicator tanks and tanks used on applicators, etc., shall be so installed that the bottom of the container and/or any outlet connection, including hose, shall not be lower than the lowest horizontal edge of the vehicle axle when fully loaded. These tanks shall be secured to prevent jarring loose, slipping, or rotating of the tanks while in service. Such supports and fastenings shall be designed to withstand a loading in any direction equal to the loaded weight of the tank when filled to the maximum permissible level with a factor of safety of at least 8.
Field welding where necessary, shall be made only on nonpressure parts that were installed by the manufacturer of the tank.
(c) While in use on farm machinery, each skid tank, applicator tank, or combination thereof shall have securely attached a container holding not less than 5 gallons of fresh water. This container shall have a suitable opening to permit the application of water to flush the eyes.
The container of fresh water required by this subsection may be attached to the tractor or other source of power used to tow the vehicle or device on which the tank is used.
1. Amendment of subsection (a) and new subsections (d) and (e) filed 3-28-75; effective thirtieth day thereafter (Register 75, No. 13).