T.1. Performance accuracy - primary and secondary shut-off devices.
T.1.1. Primary shut-off device overrides.
The required, additional attempts, in total, to override any nozzle primary shut-off device shall not increase the dispenser volume indication by more than 1/10 gallon.
T.1.2. Secondary shut-off device.
With the vapor return line blocked by fuel (simulating recirculation due to primary shut-off device failure), each attempt to dispense fuel shall result in automatic nozzle shut off before the dispenser volume indication increases more than 3/10 gallon.
T.2. Assist system inches of H2O column vacuum.
Assist vapor recovery systems shall operate at the inches of H2O column vacuum recommended by the manufacturer, but shall not exceed -10 inches of H2O column vacuum for nozzles where the spout is booted and can form a closed seal around the vehicle filler neck.
T.3. Delivery accuracy - 150 vehicle test.
The quantity of measured liquid collected in the vapor return line/lines shall not exceed both:
Note: Authority cited: Sections 12107 and 12500.5, Business and Professions Code; and Sections 41956(a) and 41956(c), Health and Safety Code. Reference: Sections 12107 and 12500.5, Business and Professions Code; and Sections 41956(a) and 41956(c), Health and Safety Code.
1. Repealer and new section filed 8-1-91; operative 9-2-91 (Register 92, No. 9).
2. Amendment of subsection T.2. filed 5-7-97; operative 6-6-97 (Register 97, No. 19).