- (a) Wood floors or subfloors in kitchens, laundry rooms, water heater compartments and any other interior areas subject to excessive moisture shall be made impervious to moisture by sealing with a listed and tested water resistant material, or by applying an overlay of approved nonabsorbent material applied with a listed and tested water resistant adhesive.
- (b) Floors under heating appliances shall not be covered with flammable materials such as carpeting.
- (c) Carpet and carpet pads shall not be installed in concealed spaces subject to excessive moisture such as under plumbing fixtures. Carpet and/or carpet pads shall not be installed beneath the bottom plate of shear or bearing walls.
Note: Authority cited: Section 18015, Health and Safety Code. Reference: Section 18028, Health and Safety Code.
History
1. Amendment filed 9-7-73; effective thirtieth day thereafter (Register 73, No. 36).
2. Amendment filed 7-25-75; designated effective 9-1-75 (Register 75, No. 30).
3. Amendment filed 12-7-79; effective thirtieth day thereafter (Register 79, No. 49).
4. Amendment of section and Note filed 9-19-2011; operative 10-19-2011 (Register 2011, No. 38).