- (a) Commercial modulars intended for installation on a foundation system at a specific location shall be designed in accordance with the wind load requirements of the California Code of Regulations, Title 24, Part 2, California Building Code (CBC), Chapter 16.
- (b) The structural system of commercial modulars, not intended for site-specific locations, shall be designed and constructed to resist the effects of a minimum basic three-second wind speed gust of not less than eighty-five (85) miles per hour (38 m/s) in an Exposure C location.
- (c) Commercial modulars intended for installation in areas subject to basic wind speed gusts in excess of an eighty-five (85) miles per hour (38 m/s) in an Exposure C location, shall have the structural system designed and constructed to comply with those higher requirements.
Note: Authority cited: Section 18015, Health and Safety Code. Reference: Section 18028, Health and Safety Code.
History
1. Amendment filed 9-7-73; effective thirtieth day thereafter (Register 73, No. 36).
2. Amendment filed 7-25-75; designated effective 9-1-75 (Register 75, No. 30).
3. Amendment filed 6-9-77; designated effective 9-1-77 (Register 77, No. 24).
4. Amendment filed 12-7-79;; effective thirtieth day thereafter (Register 79, No. 49).
5. Repealer and new section and amendment of Note filed 9-19-2011; operative 10-19-2011 (Register 2011, No. 38).