- (a) An MH-unit shall be connected to the lot drain inlet by means of a drain connector consisting of approved pipe not less than schedule 40, with listed and approved fittings and connectors, and shall not be less in size than the MH-unit drain outlet. A listed and approved flexible connector shall be provided at the lot drain inlet end of the pipe.
- (b) Drain connectors and fittings for recreational vehicles shall be listed and approved for drain and waste.
- (c) Recreational vehicles located in a park for more than three (3) months, or units with plumbing that are not self contained, shall have a drain connector complying with subsection (a).
- (d) All drain connectors and fittings shall be maintained with a grade not less than one-eighth ( ⅛ ) inch per foot. A drain connector shall be gas-tight and no longer than necessary to make the connection between the unit's drain outlet and the drain inlet on the lot.
Note: Authority cited: Section 18300, Health and Safety Code. Reference: Sections 18550, 18613 and 18630, Health and Safety Code.