Cal. Code Regs. tit. 25, § 1336
(d) Multiply the square footage obtained in the calculation described in subsection (c) by either the design wind load of the MH-unit or by fifteen (15) psf, whichever is greater, to obtain the wind load. The design wind load of the MH-unit is provided on the data plate permanently affixed to the MH-unit.
EXAMPLE: The side wall of the MH-unit measures sixty-two and one-half feet (62 ½ ′) in length and ten feet (10′) in height. The roof of the MH-unit measures sixty-three and one-half feet (62 ½ ′) in length and four and one-third feet (4 ⅓ ′) in height. These measurements result in a calculated wind load of 11,437 pounds using the above-described method.
Wind load is calculated as follows:
Note: Authority cited: Sections 18300, 18613 and 18613.4, Health and Safety Code. Reference: Section 18613.4, Health and Safety Code.