- (a) A permit shall be obtained from the enforcement agency prior to installing any regenerating water conditioning equipment on a lot. Approval of the park operator is required on all applications for a permit to install such equipment. Where the water conditioning equipment is of the regenerating type, and the park drainage system discharges into a public sewer, approval of the sanitary district or agency having jurisdiction over the public sewer is required prior to issuance of the permit.
- (b) Regenerating water conditioning equipment shall be listed and labeled by an approved listing agency.
- (c) Regenerating units shall discharge the effluent of regeneration into a trap not less than one and one-half (1 ½ ) inches in diameter connected to the park drainage system. An approved air gap shall be installed on the discharge line a minimum of twelve (12) inches above the ground. The trap need not be vented.
- (d) Electrical supply connections to regenerating water conditioning equipment shall comply with the requirements of this chapter.
Note: Authority cited: Section 18300, Health and Safety Code. Reference: Sections 18630 and 18670, Health and Safety Code.
History
1. Amendment of section and Note filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).