Cal. Code Regs. tit. 25, § 1268
(d) A park drainage system which exceeds the fixture unit loading of Table 1268-1 shall be designed by a registered engineer.
TABLE 1268-1
Drainage Pipe Diameter and Number of Fixture Units on Drainage System
Size of Drainage Pipe (Inches)
Maximum No. of Fixture Units Individually Vented System
Maximum No. of Fixture Units Wet Vented System
Terminal & Relief Vent Wet Vented System (Inches)
3
35
14
2
4
180
35
3
5
356
180
4
6
600
356
4
TABLE 1268-2
Minimum Grade and Slope of Drainage Pipe
Pipe Size (inches)
Slope per 100 ft. (inches)
Pipe Size (inches)
Slope per 100 ft. (inches)
2
25
6
8
3
20
8
4
4
15
10
3 ½
5
11
12
3
Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18630, Health and Safety Code.
1. Amendment filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).