Cal. Code Regs. tit. 23, § 2541
(d) Earthen materials used in containment structures other than cutoff walls and grout curtains shall consist of a mixture of clay and other suitable fine-grained soils which have the following characteristics, and which, in combination, can be compacted to attain the required permeability when installed. Liners made of such materials are referred to as “clay liners” in this chapter.
(e) Construction standards for waste management units other than land treatment are given on Table 4.1 and in Figure 4.1.
Table 4.1. Construction Standards for Waste Management Units1
Subsurface Barriers
Waste Mgmt Unit Classification
Type of Waste Management Unit
Clay Liner(2)
Synthetic Liner
Leachate Collection and Removal System
Interim Cover
Cutoff Walls
Grout Curtains
Capacity of Precipitation and Drainage Control Facilities
Seismic Design
Class I
Landfill
required, ≤1*10-7 cm/sec
required(7)
required, blanket type
required
≤1*10-7 cm/sec(10)
≤1*10-7 cm/sec
probable maximum precipitation
withstand maximum credible earthquake
Surface Impoundment
double liner(3) ≤1*10-7 cm/sec
required(8)
required, blanket type
≤1*10-7 cm/sec(10)
≤1*10-7 cm/sec
Waste Pile
optional(4) ≤1*10-7 cm/sec
may be(9) required
required, blanket type
required
≤1*10-7 cm/sec(10)
≤1*10-7 cm/sec
1 Applicable regulations in this article may provide for exemptions to certain requirements. Subsection 2540(d) of this article describes applicability to existing facilities.
2 All permeabilities specified in this table are maximum allowable permeabilities.
3 Outer liner shall be a clay liner; inner liner may be a synthetic liner instead of a clay liner if inspected according to Subsection 2548(f) of this article.
4 A synthetic liner alone may be allowed based on nature of waste to be contained and duration of the operation. A waste pile with a synthetic liner alone may not be closed as a landfill pursuant to Section 2583 of this chapter. The synthetic liner permeability shall be the same or less than that which would be required for a clay liner.
5 [Reserved.]
6 [Reserved.]
7 Synthetic inner liner required in addition to a clay outer liner unless exempted pursuant to Subsection2510(b) of this chapter.
8 Synthetic inner liner required in addition to a clay liner unless the surface impoundment is closed according to Subsection 2582(b)(1)of this chapter, or unless exempted pursuant to Subsection 2510(b) of this chapter.
9 Synthetic inner liner required unless the pile is closed according to Subsection 2583(a)(1), or unless exempted pursuant to Subsection 2510(b) of this chapter.
10 Cutoff walls required where there is potential for lateral movement of fluid, including waste or leachate.
)
Note: Authority cited: Section 1058, Water Code. Reference: Sections 13172 and 13360, Water Code.
1. Amendment of Table 4.1 and new footnotes 7, 8 and 9 filed 6-12-85; effective upon filing pursuant to Government Code Section 11346.2(d) (Register 85, No. 24).
2. Amendment of subsections (d) and (e), Table 4.1 and Figure 4.1, and repealer of figure 4.2 filed 6-18-97; operative 7-18-97 (Register 97, No. 25).