(a) The applicant shall follow all the following specific requirements for attaching utilities to cross-drainage structures:
- (1) Anchor bolt locations shall not intercept the critical reinforcing steel of the cross-drainage structure.
- (2) After installation, exposed metal surfaces shall be cleaned and primed with paint of the same quality as that used for shop coat.
- (3) Utilities shall not be permitted to be installed inside the cross-drainage structure.
- (4) Lateral supports for the utility shall withstand a seismic loading of no less than 0.5g (Include Pipe Material and Content inside the pipe in the calculation). Spacing of supports shall not exceed a maximum of twelve (12) feet.
- (5) Anchor bolts shall be hot-dipped galvanized double wedge conforming to Federal Specification FF-S-325 Amendment No. 3, Group II, Type 4, Class 1; and shall be installed according to the manufacturer's instructions, or equivalent.
Note: Authority cited: Section 12899.9, Water Code. Reference: Sections 12899, 12899.1(a), 12899.1(c) and 12899.2, Water Code.
History
1. New section filed 4-22-2015; operative 7-1-2015 (Register 2015, No. 17).