Cal. Code Regs. tit. 20, § 1604
(a) Refrigerators, Refrigerator-Freezers, and Freezers.
(2) The test methods for commercial refrigerators, commercial refrigerator-freezers, and commercial freezers are shown in Table A-1.
Table A-1
Commercial Refrigerator, Refrigerator-Freezer, and Freezer Test Methods
Appliance
Test Method
Automatic commercial ice makers
10 C.F.R. sections 431.133 (January 19, 2025) and 431.134 (January 19, 2025)
Refrigerated bottled or canned beverage vending machines
10 C.F.R. sections 431.293 (January 19, 2025) and 431.294 (January 19, 2025)
Refrigerated buffet and preparation tables
ANSI/ASTM F2143-01
Other commercial refrigerators, refrigerator-freezers, and freezers, with doors
10 C.F.R. sections 431.63 (January 19, 2025) and 431.64 (January 19, 2025)
Other commercial refrigerators, refrigerator-freezers, and freezers, without doors
10 C.F.R. sections 431.63 (January 19, 2025) and 431.64 (January 19, 2025)
Walk-in coolers and walk-in freezers
10 C.F.R. sections 431.303 (January 19, 2025) and 431.304 (January 19, 2025)
(4) The test method for water dispensers is EPA Energy Star Program Requirements for Bottled Water Coolers (2004).
Exception to Section 1604(a)(4) of this Article: Water dispensers equipped with an integral, automatic timer. Water dispensers equipped with an integral, automatic timer shall not be tested using Section 4)D, “Timer Usage,” of the referenced test method.
(b) Room Air Conditioners, Room Air-Conditioning Heat Pumps, Packaged Terminal Air Conditioners, and Packaged Terminal Heat Pumps. The test methods for room air conditioners, room air-conditioning heat pumps, packaged terminal air conditioners, and packaged terminal heat pumps are shown in Table B-1.
Table B-1
Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods
Appliance
Test Method
Room air conditioners and room air-conditioning heat pumps
10 C.F.R. section 430.23(f) (Appendix F to subpart B of part 430) (January 19, 2025)
Packaged terminal air conditioners and packaged terminal heat pumps
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
(c) Central Air Conditioners, Air Filters, and Heat Pump Water-Heating Packages.
(2) For each basic model of central air conditioner and heat pump, test the individual model and combination as required in 10 C.F.R. section 429.16(b)(2) (August 1, 2025).
Table C-1
Central Air Conditioner Test Methods
Appliance
Test Method
Computer Room Air Conditioners
evaporatively cooled
ANSI/ASHRAE 127-2001
air-cooled, glycol-cooled, water-cooled
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
Other electric-powered unitary air-conditioners and electric-powered heat pumps
air-cooled air conditioners and air-source heat pumps
< 65,000 Btu/hr, single-phase
10 C.F.R. section 430.23(m) (Appendix M to subpart B of part 430) (for models manufactured before January 1, 2023, only) (August 1, 2025)
10 C.F.R. section 430.23(m) (Appendix M1 to subpart B of part 430) (for models manufactured on or after January 1, 2023, only) (August 1, 2025)
< 65,000 Btu/hr, three-phase
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
≥ 65,000 and < 760,000 Btu/hr evaporatively cooled air conditioners
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
< 240,000 Btu/hr
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
water-cooled air conditioners and water-source heat pumps
< 240,000 Btu/hr
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
ground water-source heat pumps
ARI/ISO-13256-1:1998
ground-source closed-loop heat pumps
ARI/ISO-13256-1:1998
Variable Refrigerant Flow Multi-split Systems
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps
10 C.F.R. sections 431.95 (January 19, 2025) and 431.96 (January 19, 2025)
Gas-fired air conditioners and gas-fired heat pumps
ANSI Z21.40.4-1996 as modified by CEC, Efficiency Calculation Method for Gas-Fired Heat Pumps as a New Compliance Option (1996)
(3) Air Filters. The test methods for air filters manufactured on or after July 1, 2024, are shown in Table C-2.
(A) Manufacturers shall test each basic model of air filter at dimensions determined by the manufacturer.
Table C-2 Air Filter Test Methods
Appliance Performance Criteria
Test Method
Air Filter Pressure Drop
AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017
Minimum Efficiency Reporting Value (MERV)
ANSI/ASHRAE Standard 52.2-2017
Air Filter Particle Size Efficiency
AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017
Dust Holding Capacity
AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017
* MERV not reportable for models being tested to AHRI Standard 680 (I-P)-2017 only
(B) The following procedure shall be used to calculate the airflow rate value in cubic feet per minute at an initial resistance pressure difference of 0.1 inches water column:
1. The value or airflow rate at an initial resistance of 0.1 inches water column shall be determined from a least-squares fit to airflow rate in cfm, as a function of initial resistance static pressure difference in inches water column, using:
Q = C x dPn, where Q=airflow rate in cfm, dP=initial resistance pressure difference in inches water column, and C and n are the coefficients determined in the least squares fit.
(d) Portable Air Conditioners, Evaporative Coolers, Ceiling Fans, Ceiling Fan Light Kits, Whole House Fans, Residential Exhaust Fans, Dehumidifiers, Residential Furnace Fans, and Commercial and Industrial Fans and Blowers.
(1) The test methods for portable air conditioners, evaporative coolers, ceiling fans, ceiling fan light kits, whole house fans, residential exhaust fans, dehumidifiers, residential furnace fans, and commercial and industrial fans and blowers are shown in Table D-3.
Table D-3
Testing Requirements for the following Appliances
Appliance
Test Method
Spot Air Conditioners
ANSI/ASHRAE 128-2001
Single-Duct and Dual-Duct Portable Air Conditioners
10 C.F.R. section 430.23(dd) (Appendix CC to subpart B of part 430) (January 19, 2025)
Ceiling Fans 1
10 C.F.R. section 430.23(w) (Appendix U to subpart B of part 430) (January 19, 2025)
Ceiling Fan Light Kits
10 C.F.R. section 430.23(x) (Appendix V to subpart B of part 430) (January 19, 2025)
Evaporative Coolers 2
ANSI/ASHRAE 133-2008 for packaged direct evaporative coolers and packaged indirect/direct evaporative coolers; ANSI/ASHRAE 143-„2007 for packaged indirect evaporative coolers
Whole House Fans
HVI-Publication 916
29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2.
Use setups for whole house comfort ventilators.
Dehumidifiers
10 C.F.R. section 430.23(z) (Appendix X to subpart B of part 430, active mode portion only)
Portable Dehumidifiers and Whole-Home Dehumidifiers Manufactured On or After June 13, 2019
10 C.F.R. section 430.23(z) (Appendix X1 to subpart B of part 430) (January 19, 2025)
Residential Exhaust Fans
HVI-Publication 916
29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2.
Residential Furnace Fans
10 C.F.R. section 430.23(cc) (Appendix AA to subpart B of part 430) (January 19, 2025)
Commercial and Industrial Fans and Blowers
10 C.F.R. section 431.174 (Appendix A to Subpart J of Part 431) 3 (January 19, 2025)
1 Very small-diameter ceiling fans are not required to be tested, unless those fans also meet the definition of “low-speed small-diameter ceiling fan” found in section 1602(d) of this Article.
2 Not including evaporative coolers whose fans or blowers are within the scope of the testing requirements for commercial and industrial fans and blowers.
3 Including but not limited to provisions on alternative efficiency determination method (AEDM) and additional testing requirements concerning selection of models to be tested if an AEDM is to be applied, in 10 C.F.R. sections 429.69 (January 19, 2025) and 429.70 (August 1, 2025).
(e) Space Heating Products.
(3) Combination Space-Heating and Water-Heating Appliances. The test method for combination space-heating and water-heating appliances is ANSI/ASHRAE 124-2007.
Table E-1
Space Heating Product Test Methods
Appliance
Test Method
Central furnaces
< 225,000 Btu/hr, single phase
10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) (January 19, 2025)
< 225,000 Btu/hr, three phase
10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) (January 19, 2025) or 10 C.F.R. sections 431.75 (January 19, 2025) and 431.76 (January 19, 2025) (at manufacturer's option)
≥ 225,000 Btu/hr
10 C.F.R. sections 431.75 (January 19, 2025) and 431.76 (January 19, 2025)
Infrared gas space heaters
patio heaters
ASTM F2644-07
high-intensity infrared heaters
ANSI Z83.19-2001
low-intensity infrared heaters
ANSI Z83.20-2001
Gas duct furnaces
ANSI Z83.8-2002
Boilers
< 300,000 Btu/hr
10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) (January 19, 2025)
≥ 300,000 Btu/hr
10 C.F.R. sections 431.85 (January 19, 2025) and 431.86 (January 19, 2025)
Vented home heating equipment
10 C.F.R. section 430.23(o) (Appendix O to subpart B of part 430) (January 19, 2025)
(f) Water Heaters.
(2) Water heaters that are Regulated Under subpart G of 10 C.F.R. part 431.
The test methods for water heaters that are regulated under subpart G of 10 C.F.R. part 431 are found at 10 C.F.R. sections 431.105 (January 19, 2025) and 431.106 (January 19, 2025).
(g) Pool Heaters; Portable Electric Spas; Residential Pool Pump and Motor Combinations, and Replacement Residential Pool Pump Motors; and Pumps, Dedicated-Purpose Pool Pumps, and Replacement Dedicated-Purpose Pool Pump Motors.
(1) Test Methods for Pool Heaters.
The test method for fossil fuel-fired pool heaters, electric resistance pool heaters, and electric heat pump pool heaters is 10 C.F.R. section 430.23(p) (Appendix P to subpart B of part 430) (January 19, 2025).
(2) Test Method for Portable Electric Spas.
(3) Test Methods for Pumps, Dedicated-Purpose Pool Pumps, and Replacement Dedicated-Purpose Pool Pump Motors.
(C) A replacement dedicated-purpose pool pump motor manufactured on or after July 19, 2021, shall be tested in accordance with CSA-C747-09 (Reaffirmed 2014), “Energy Efficiency Test Methods for Small Motors” at full load and maximum operating speed. If a drive is sold or offered for sale with the replacement dedicated-purpose pool pump motor, the input power of the drive while the drive is connected to the motor shall be used to determine nominal efficiency and power factor per the test procedure.
2. Power factor shall be calculated as: Single phase motors:
Power Factor (%) = 100 x Input Power (W)/(Voltage(V) x Amps (A))
Three phase motors:
Power Factor (%) = 100 x Input Power (W)/(Voltage(V) x Amps(A) x 1.73)
where Voltage and Amps are the measured root mean square (rms) voltage and current.
(h) Plumbing Fittings.
(2) Showerheads. The test methods for showerheads are:
(i) Plumbing Fixtures.
The test methods for plumbing fixtures are:
(j) Fluorescent Lamp Ballasts and Deep-Dimming Fluorescent Lamp Ballasts.
(2) Deep-Dimming Fluorescent Lamp Ballasts. Deep-dimming fluorescent lamp ballasts shall be tested using 10 C.F.R. Section 430.23(q) (Appendix Q to subpart B of part 430) (January 19, 2025) (referred to as the “federal test method” in the following subsections), modified as follows:
(A) The control signal to the ballast shall indicate full output. The arc power of all connected lamps shall be measured and then added together. This result will be referred to as “maximum arc power.” An appropriate lighting control shall be selected to achieve the control signal used to determine the maximum arc power and to tune the ballast to the appropriate dimming levels. The controls shall be selected by using the following methodology:
(D) The weighted ballast luminous efficacy shall be calculated using the following formula and table:
Weighted ballast luminous efficacy = BLE100 x w100 + BLE80 x w80 + BLE50 x w50
Where the time values (w100, w80, w50) are taken from the appropriate table below:
Table J-1
Percentage Time of Operation Table
Time Variable
Measurements taken
P80, P50
P80, No P50
No P80, P50
No P80, No P50
W100
0.2
0.35
0.45
1
W80
0.5
0.65
0
0
W50
0.3
0
0.55
0
(k) Lamps.
(4) The optional test methods for state-regulated small diameter directional lamps and state-regulated LED lamps are shown in Table K-1. Optional test procedures are conditionally required depending on manufacturer claims of performance as described in sections 1607(d)(12) of this Article and 1606 Table X of this Article. For certification, compliance, and enforcement purposes, the sampling provisions in 10 C.F.R. section 429.56 (August 1, 2025) shall be used.
Table K-1
Optional Test Methods for State-Regulated LED Lamps and LED State-Regulated Small Diameter Directional Lamps
Measurement
Test Procedure
Flicker
Title 24, part 6, Joint Appendix 10 (2015), tested at both 100 percent and 20 percent output. Lamps with a percent amplitude modulation (percent flicker) less than 30 percent at frequencies less than 200 Hz shall report “yes” for “reduced flicker operation” described in section 1606 of this Article, otherwise report “no”.
Lumen Maintenance, Rated Life, and Survival Rate for Compliance with Title 24 Joint Appendix 8 and minimum dimming level
Title 24, part 6, Joint Appendix 8 (2015).
Audible Noise
ENERGY STAR Recommended Practice -- Noise (2013) with the following modification: measurements shall be taken at 100 percent output as well as at 20 percent output if dimmable.
(l) Emergency Lighting.
Emergency Lighting. The test method for illuminated exit signs is 10 C.F.R. section 431.204(b) (January 19, 2025).
(m) Traffic Signal Modules.
Traffic Signal Modules. The test method for traffic signal modules for vehicle or pedestrian control is 10 C.F.R. section 431.224 (January 19, 2025).
(n) Luminaires and Torchieres.
(1) Torchieres.
There is no test method for torchieres.
(2) Metal Halide Luminaires.
The test method for metal halide luminaires is ANSI C82.6-2005. Ballasts may be tested separately, outside the luminaire. A sample of at least five ballasts shall be tested for each lamp wattage for which the luminaire and ballasts are rated. The average of these tests shall be used for certification and compliance purposes.
Ballasts efficiency for High Intensity Discharge (HID) luminaire means the efficiency of a lamp and ballast combination expressed as a percentage and calculated by Efficiency = Pout / Pin, as measured. Pout is the measured operating lamp wattage and Pin is the measured operating input wattage.
The lamp, and the capacitor when it is provided, is to constitute a nominal system in accordance with ANSI C78.43-2004. Pin and Pout are to be measured after lamps have been stabilized according to Section 4.4 of ANSI C82.6-2005 using a wattmeter with accuracy specified in Section 4.5 of ANSI C82.6-2005 for ballasts with a frequency of 60 Hz and shall have a basic accuracy of ± 0.5 percent at the higher of (a.) three times the output operating frequency of the ballast, or (b.) 2 kHz for ballast with a frequency greater than 60 Hz.
(3) Under-Cabinet Luminaires.
The test method for under-cabinet luminaires is 10 C.F.R. 430.23(q) (Appendix Q to subpart B of part 430 (2015)).
(o) Dishwashers.
The test method for dishwashers is 10 C.F.R. section 430.23(c) (Appendix C1 to subpart B of part 430) (January 19, 2025).
(p) Clothes Washers.
(q) Clothes Dryers.
The test methods for clothes dryers are 10 C.F.R. section 430.23(d) (Appendix D1 or Appendix D2 to subpart B of part 430) (August 1, 2025). Manufacturers must use a single appendix for all representations, including certifications of compliance, and may not use appendix D1 for certain representations and appendix D2 for other representations.
(r) Cooking Products and Food Service Equipment.
The test methods for cooking products and food service equipment are shown in Table R-1.
Table R-1
Cooking Product and Food Service Equipment Test Methods
Appliance
Test Method
Microwave ovens
10 C.F.R. section 430.23(i) (Appendix I to subpart B of part 430) (January 19, 2025)
Conventional cooktops and combined cooking products
10 C.F.R. section 430.23(i) (Appendix I1 to subpart B of part 430) (January 19, 2025)
Commercial hot food holding cabinets
ANSI/ASTM F2140-01 (Test for idle energy rate-dry test) and US EPA's Energy Star Guidelines, “Measuring Interior Volume” (Test for interior volume)
Commercial convection ovens
ANSI/ASTM F1496-99 (Test for energy input rate and idle energy consumption only)
Commercial range tops
ANSI/ASTM F1521-96 (Test for cooking energy efficiency only)
(s) Electric Motors and Compressors.
(t) Distribution Transformers.
The test method for distribution transformers is 10 C.F.R. section 431.193 (Appendix A of subpart K) (August 1, 2025).
(u) External Power Supplies.
(v) Computers, Computer Monitors, Televisions, Signage Displays, and Consumer Audio and Video Equipment.
(2) Televisions and Signage Displays.
(3) Computer Monitors. The test method for computer monitors is the ENERGY STAR Program Requirements for Displays, Final Test Method (September 2015), with the following modifications:
(B) A computer monitor shall be tested as required by the test procedure for each of the following:
(4) Computers. The test method for computers is the ENERGY STAR Program Requirements for Computers, Final Test Method (Rev. March-2016), with the following modifications:
(B) The total annual energy consumption of a computer shall be calculated using Equation 1 in Section 3 of the ENERGY STAR Program Requirements for Computers, Eligibility Criteria Version 6.1 (Rev. March-2016).
(C) The expandability score calculation shall be included in test reports and shall be calculated as follows:
3. Add 100 to the score.
Table V-1
Interface Types and Scores for Expandability Score Calculation
Interface Type
Interface Score
USB 2.0 or less
5
USB 3.0 or 3.1 Gen 1
10
USB 3.1 Gen 2
15
USB ports or Thunderbolt 3.0 or greater that can provide 100 or more watts of power
100
USB ports or Thunderbolt 3.0 or greater that can provide from 60 or more to less than 100 watts of power
60
USB ports or Thunderbolt 3.0 or greater that can provide from 30 or more to less than 60 watts of power
30
Thunderbolt 3.0 or greater or USB ports that are not otherwise addressed in Table V-1 and that cannot provide 30 or more watts of power
20
Unconnected USB 2.0 motherboard header
10 per header
Unconnected USB 3.0 or 3.1 Gen 1 motherboard header
20 per header
PCI slot other than PCIe x16 (only count mechanical slots)
25
PCIe x16 or higher (only count mechanical slots)
75
Thunderbolt 2.0 or less
20
M.2 (except key M)
10
IDE, SATA, eSATA
15
M.2 key M, SATA express, U.2
25
Integrated liquid cooling
50
Either:
100
1) CPU and motherboard support for 4 or more channels of system memory and at least 8 GB of installed and compatible system memory; or
2) At least 8 GB of system memory installed on a 256 bit or greater memory interface.
(D) A computer monitor used in the testing of desktop computers shall have a native resolution of at least 1920x1080 pixels and use progressive scanning. The computer operating system shall be set to operate at a minimum of 1920x1080 pixels and progressive scanning. If multiple display connections are available on the computer, choose the correct connection using the following criteria:
(K) For computers with cyclical behavior where operation without a battery pack when connected to the mains power source is not a supported configuration and where the normal measurement time would not capture one or more complete cycles, short-idle, long-idle, sleep, and off mode power measurements shall be tested in a modified manner from the test procedure described in IEC 62623:2012:
(w) Battery Chargers and Battery Charger Systems.
(2) Test Method for Small Battery Charger Systems. The test method for small battery charger systems that are not federally regulated battery chargers, federally regulated uninterruptible power supplies, battery backups, or non-federally regulated uninterruptible power supplies is 10 C.F.R. section 430.23(aa) (Appendix Y to subpart B of part 430) (Jan. 1, 2017).
(4) Test Method for Large Battery Charger Systems. The test method for large battery charger systems that are not federally regulated battery chargers or federally regulated uninterruptible power supplies is Energy Efficiency Battery Charger System Test Procedure Version 2.2 dated November 12, 2008 and published by ECOS and EPRI Solutions with the following modifications:
(A) The test procedure shall be conducted for 100, 80, and 40 percent discharge rates for only one charge profile, battery capacity, and battery voltage. The manufacturer shall test one battery and one charge profile using the following criteria:
(x) Landscape Irrigation Equipment.
(1) Spray Sprinkler Bodies.
(A) The test method for a spray sprinkler body is Appendix B of the WaterSense® Specification for Spray Sprinkler Bodies Version 1.0, September 21, 2017. For certification, compliance, and enforcement purposes, the sampling provisions in Appendix B of the WaterSense® Specification for Spray Sprinkler Bodies Version 1.0, September 21, 2017 shall be used.
The following documents are incorporated by reference in section 1604.
Number
Title
CALIFORNIA ENERGY COMMISSION TEST METHODS
CEC/Gas-Fired Heat Pumps
Efficiency Calculation Method for Gas-Fired Heat Pumps as a Exceptional Method (1996) New Compliance Option (1996)
California Title 24, part 6, Joint Appendix 8 JA-8 -- 2015
Qualification Requirements for High Efficacy Light Sources
California Title 24, part 6, Joint Appendix 10 JA-10 -- 2015
Test Method for Measuring Flicker of Lighting Systems and Reporting Requirements
Copies available from:
CALIFORNIA ENERGY COMMISSION
ENERGY HOTLINE
715 P STREET, MS-25
SACRAMENTO, CALIFORNIA 95814
PHONE: (916) 654-5106
FAX: (916) 654-4304
FEDERAL TEST METHODS
All C.F.R. documents listed below are the January 19, 2025, versions, unless otherwise stated:
C.F.R., Title 10, sections 429.12, 429.16 (August 1, 2025), 429.56 (August 1, 2025), 429.63, 429.69, and 429.70 (August 1, 2025)
C.F.R., Title 10, section 430.23 (August 1, 2025), and 10 C.F.R. Appendixes A, B, C1, D1 (August 1, 2025), D2 (August 1, 2025), E (August 1, 2025), F, H, H (January 1, 2023), I, I1, J (August 1, 2025), J2 (August 1, 2025), M (August 1, 2025), M1 (August 1, 2025), N, O, P, Q, R, S, T, U, V, W (August 1, 2025), X, S1, Y (August 1, 2025), Y (January 1, 2016), Y (January 1, 2017), Y1, Z, AA, BB (August 1, 2025), CC, and DD (August 1, 2025) of subpart B of part 430
C.F.R., Title 10, sections 431.15, 431.16, 431.17, 431.18, 431.19, 431.20, and 431.21
C.F.R., Title 10, sections 431.63 and 431.64
C.F.R., Title 10, sections 431.75 and 431.76
C.F.R., Title 10, sections 431.85 and 431.86
C.F.R., Title 10, sections 431.95 and 431.96
C.F.R., Title 10, sections 431.105 and 431.106
C.F.R., Title 10, sections 431.133 and 431.134
C.F.R., Title 10, section 431.154
C.F.R., Title 10, section 431.174, Appendix A to Subpart J of 10 C.F.R., § 431
C.F.R., Title 10, section 431.193
C.F.R., Title 10, section 431.204(b)
C.F.R., Title 10, section 431.224
C.F.R., Title 10, sections 431.263 and 431.264
C.F.R., Title 10, sections 431.293 and 431.294
C.F.R., Title 10, sections 431.303 and 431.304
C.F.R., Title 10, section 431.344, Appendix A to Subpart T of 10 C.F.R., § 431 (August 1, 2025)
C.F.R., Title 10, sections 431.443, 431.444, and 431.445
C.F.R., Title 10, section 431.464(a) Appendix A to Subpart Y of 10 C.F.R., § 431 (August 1, 2025)
C.F.R., Title 10, section 431.464(b), Appendix C to Subpart Y of 10 C.F.R., § 431
C.F.R., Title 10, section 431 subpart G
Number
Title
Copies available from:
SUPERINTENDENT OF DOCUMENTS
U.S. GOVERNMENT PRINTING OFFICE
WASHINGTON, DC 20402
www.ecfr.gov
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA)
ENERGY STAR® Program
Requirements for
Bottled Water Coolers (2004)
ENERGY STAR® Program Requirements for Computers, subparts Eligibility Criteria
Version 6.1 (Rev. March-2016) and Final
Test Method (Rev. March-2016)
ENERGY STAR® Program Requirements f for Displays, subpart Final Test Method
(Rev. Sep-2015)
EPA “Test Method for Calculating the Energy Efficiency of Single-Voltage External AC-DC and AC-AC Power Supplies”
(August 11, 2004)
Energy Star Guidelines, “Measuring Interior Volume” (Test for measuring interior volume of commercial hot food holding cabinets)
ENERGY STAR Recommended Practice -- Noise (2013)
EPA ENERGY STAR® Program Requirements Product Specification for Lamps (Light Bulbs)
Version 1.1 (August 2014).
Copies available from:
US EPA
CLIMATE PROTECTION PARTNERSHIP
ENERGY STAR PROGRAMS HOTLINE &
DISTRIBUTION
(MS-6202J)
1200 PENNSYLVANIA AVE NW
WASHINGTON, DC 20460
www.energystar.gov
Appendix B of the WaterSense®
Specification for
Spray Sprinkler Bodies
Version 1.0 (Dated September 21, 2017)
Copies available from:
WATERSENSE®
U.S. ENVIRONMENTAL PROTECTION AGENCY
OFFICE OF WASTEWATER MANAGEMENT
(4204M)
1200 PENNSYLVANIA AVENUE, N.W.
WASHINGTON, D.C. 20460
HTTPS://WWW.EPA.GOV/WATERSENSE
AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI)
AHRI Standard 680 (I-P)-2017
2017 Standard for Performance Rating of Residential Air Filter Equipment
Copies available from:
AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI)
2111 WILSON BLVD, SUITE 500
ARLINGTON, VA 22201
PHONE: (703) 524-8800
FAX: (703) 562-1942
http://www.ahrinet.org/
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI/ASHRAE Standard 52.2-2017
Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
ANSI C78.43-2004
American National Standards for Electric
Lamps -- Single-Ended Metal Halide Lamps
ANSI C82.6-2005
Ballasts for High Intensity Discharge
Lamps -- Method of Measurement
ANSI Z21.10.3-1998
Standard for Gas Water Heaters, Volume III, Storage Water Heaters with Input Ratings
Above 75,000 Btu per hour, Circulating and Instantaneous
ANSI Z21.40.4-1996
Performance Testing and Rating of Gas-Fired Air-Conditioning and Heat Pump Appliances
ANSI Z83.8-2002
Standard for Gas Unit Heaters and Gas-Fired Duct Furnaces
ANSI Z83.19-2001
Standard for Gas-Fired High-Intensity Infrared Heaters
ANSI Z83.20-2001
Standard for Gas-Fired Low-Intensity Infrared Heaters
ANSI/AHRI 550-590 (I-P) 2011
Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle
Copies available from:
AMERICAN NATIONAL STANDARDS INSTITUTE
1819 L STREET, NW, 6TH FLOOR
WASHINGTON DC 20036
www.ansi.org
PHONE: (202) 293-8020
FAX: (202) 293-9287
AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)
ASME A112.19.2/CSA B45.1-2013
Ceramic Plumbing Fixtures
ASME A112.18.1-2012 & 2018/CSA B125.1-2012 & 2018
Plumbing Supply Fittings
Copies available from:
ASME HEADQUARTERS
TWO PARK AVENUE
NEW YORK, NY 10016-5990
www.asme.org
PHONE: 800-843-2763 (U.S./CANADA)
001-800-843-2763 (MEXICO)
973-882-1170 (OUTSIDE NORTH AMERICA)
EMAIL: [email protected]
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)
ANSI/ASHRAE 118.2-1993
Method of Testing for Rating Residential Water Heaters
ANSI/ASHRAE 124-2007
Method of Testing for Rating Combination
Space-Heating and Water-Heating
Appliances
ANSI/ASHRAE 127-2001
Method of Testing for Rating Computer and
Data Processing Room Unitary
Air-Conditioners
ANSI/ASHRAE 128-2001
Method of Rating Spot Unitary Air Conditioners
ANSI/ASHRAE 133-2008
Method of Testing Direct Evaporative Air Coolers
ANSI/ASHRAE 143-2007
Method of Test for Rating Indirect Evaporative Coolers
ANSI/ASHRAE 146-1998
Method of Testing and Rating Pool Heaters
Copies available from:
AMERICAN SOCIETY OF HEATING,
REFRIGERATING AND AIR-CONDITIONING
ENGINEERS
1791 TULLIE CIRCLE N.E.
ATLANTA, GA 30329
WWW.ASHRAE.ORG
PHONE: (800) 527-4723 (U.S./CANADA) OR
(404) 636-8400
FAX: (404) 321-5478
ASTM INTERNATIONAL
ANSI/ASTM F1496-99
Standard Test Method for Performance of Convection Ovens
ANSI/ASTM F1521-96
Standard Test Methods for Performance of Range Tops
ANSI/ASTM F2140-01
Standard Test Method for the Performance of Hot Food
Holding
Cabinets
ANSI/ASTM F2143-01
Standard Test Method for the Performance of Refrigerated
Buffet and
Preparation Tables
ASTM F2644-07
Standard Test Method for Performance of Commercial Patio Heaters
Copies available from:
ASTM
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
www.astm.org
Phone: 1-877-909-2786
CANADIAN STANDARDS ASSOCIATION (CSA)
CSA B45.1-2013
Ceramic Plumbing Fixtures
CSA C747-09 (reaffirmed 2014)
Energy efficiency test methods for small motors
Copies available from:
CANADIAN STANDARDS ASSOCIATION
178 REXDALE BLVD.
TORONTO, ONTARIO, CANADA, M9W 1R3
PHONE: (416) 747-4044
http:/shop.csa.ca/
ECOS CONSULTING
Energy Efficiency Battery Charger System Test Procedure Version 2.2 dated November 12, 2008
Copies available from:
ECOS CONSULTING
801 FLORIDA ROAD, # 11
DURANGO, CO 81301
HTTP://WWW.EFFICIENTPRODUCTS.ORG/
PHONE: (970) 259-6801
FAX: (970) 259-8585
ECOVA
Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.7 (March 1, 2014)
Copies available from:
PLUG LOAD SOLUTIONS BY ECOVA
www.plugloadsolutions.com
PHONE: (971) 201-4180
HOME VENTILATING INSTITUTE (HVI)
HVI-Publication 916
29 September 2015 HVI
Air-flow Test Procedure
Copies available from:
HOME VENTILATING INSTITUTE
1000 N. RAND RD., SUITE 214
WAUCONDA, IL 60084
WWW.HVI.ORG
PHONE: (847) 526-2010
FAX: (847) 526-3993
ILLUMINATING ENGINEERING SOCIETY (IES)
IES LM-84-14
Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires
IES TM-28 (2014)
Projecting Long-Term Luminous Flux Maintenance of LED Lamps and Luminaires
Copies available from:
ILLUMINATING ENGINEERING SOCIETY
120 WALL STREET, 17TH FLOOR
NEW YORK, NY 10005-4001
WWW.IES.ORG
PHONE: (212) 248-5000
FAX: (212) 248-5617/8
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
IEC 62087 (2002)(E)
Methods of Measurement for the Power Consumption of Audio, Video, and Related Equipment.
IEC 62087:2008(E), Edition 2.0
Methods of Measurement for the Power Consumption of Audio, Video, and Related Equipment
IEC 62087:2011
Methods of measurement for the power consumption of audio, video and related equipment
IEC 62301:2011
Household electrical appliances -- Measurement of standby power
IEC 62623:2012
Desktop and notebook computers -- Measurement of energy consumption
Copies available from:
IEC CENTRAL OFFICE
3, RUE DE VAREMBÉ
P.O. BOX 131
CH - 1211 GENEVA 20
SWITZERLAND
PHONE: +41 22 919 02 11
INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO)
ISO 13256-1-1998
Water-source heat pumps-Testing and rating for performance-part 1: Water-to-air and brine-to-air heat pumps
Copies available from:
ISO CENTRAL SECRETARIAT
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO)
1, RUE DE VAREMBÉ, CASE POSTALE 56
CH-1211 GENEVA 20, SWITZERLAND
WWW.ISO.ORG
PHONE: +41 22 749 01 11
FAX: +41 22 733 34 30
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
IEEE 114-2001
Standard Test Procedures for Single-Phase Induction Motors
IEEE 802.3-2015
IEEE Standard for Ethernet
IEEE 802.11-2012
IEEE Standard for Information technology -- Telecommunications and information exchange between systems
Local and metropolitan area networks -- Specific requirements
Part 11: Wireless LAN Medium Access
Control (MAC) and Physical Layer (PHY)
Specifications
Copies available from:
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
PUBLICATIONS OFFICE
10662 LOS VAQUEROS CIRCLE
PO BOX 3014
LOS ALAMITOS, CA 90720-1264
WWW.IEEE.ORG
PHONE: (714) 821-8380
FAX: (714) 821-4010
THE POOL AND HOT TUB ALLIANCE
ANSI/APSP/ICC-14 2019
American National Standard for Portable Electric Spa Energy Efficiency
Copies available from:
Pool & Hot Tube Alliance
2111 Eisenhower Avenue, Suite 500
Alexandria, VA 22314-4695
PHTA.org
Phone: (703) 838-0083
UNIFIED EXTENSIBLE FIRMWARE INTERFACE FORUM
Advanced Configuration and Power Interface Specification Revision 5.0 (December 6, 2011) and Advanced Configuration and Power Interface Specification Revision 5.0 Errata A (November 13, 2013)
Advanced Configuration and Power Interface Specification
Copies available from:
UEFI FORUM ADMINISTRATION
3855 SW 153RD DRIVE
BEAVERTON, OR 97003 USA
www.uefi.org
PHONE: +1 503-619-0864
FAX: +1 503-644-6708
Note: Authority cited: Sections 25213, 25218(e), 25401.9, 25402(a)-25402(c) and 25960, Public Resources Code; and Sections 16, 26 and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015). Reference: Sections 25216.5(d), 25401.9, 25402(a)-25402(c) and 25960, Public Resources Code; and Section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).
1. Amendment filed 7-21-82; effective thirtieth day thereafter (Register 82, No. 30). For prior history, see Register 80, No. 23.
2. New subsection (g) filed 10-1-82; designated effective 6-2-83 (Register 82, No. 40).
3. Amendment of Table C-2 filed 1-3-83; effective thirtieth day thereafter (Register 83, No. 2).
4. Amendment of subsection (f) filed 1-14-83; effective thirtieth day thereafter (Register 83, No. 3).
5. Amendment of subsection (d)(2) filed 1-20-83; effective thirtieth day thereafter (Register 83, No. 7).
6. Editorial correction of subsections (a) and (b) and Tables A and B (Register 83, No. 18).
7. Amendment of subsection (a) filed 3-26-85; effective thirtieth day thereafter (Register 85, No. 13).
8. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 18).
9. Amendment filed 5-22-85; effective thirtieth day thereafter (Register 85, No. 21).
10. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 21).
11. Amendment filed 7-20-87; operative 8-19-87 (Register 85, No. 30).
12. Amendment filed 8-29-88; operative 9-28-88 (Register 88, No. 37).
13. Amendment of subsections (a)-(c), new subsection (d) reserved, and renumbering and amendment of former subsections (d)-(g) to subsections (e)-(h) filed 6-5-90; operative 7-5-90 (Register 90, No. 31).
14. Amendment filed 11-6-91; operative 12-6-91 (Register 92, No. 9).
15. Amendment of Table F-2 filed 1-16-92; operative 1-16-92 pursuant to Government Code section 11346.2 (d) (Register 92, No. 15).
16. Amendment of subsection (f)(2) and Table F-2, new Table F-3, amendment of subsection (f)(3), renumbering and amendment of Table F-3 to Table F-4, and amendment of subsection (f)(4) and renumbering of Table F-4 to F-5 filed 7-23-92; operative 8-24-92 (Register 92, No. 35).
17. Repealer and new section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).
18. Amendment of subsection (f)(5)(E) filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.
19. Certificate of Compliance as to 4-1-2003 order transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).
20. Amendment of subsection (p) and list of incorporated documents filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).
21. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).
22. Amendment of Table A-1, subsection (a)(4), Tables B-1, D, E-1 and F-1, subsections (h)(1), (j)-(k), (n)(3) and (o), Table P-1, subsection (q), Table R, subsections (s) and (u)(1) and federal test methods filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
23. Amendment of subsection (u)(1) and Note filed 6-22-2006; operative 6-22-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 25).
24. Amendment of Table D and subsections (f)(5)(F), (k) and (n)(2) and amendment of list of incorporated documents filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).
25. Amendment of subsection (c) -- Table C-1, subsection (s) and list of incorporated documents filed 8-22-2007; operative 9-17-2007 pursuant to Government Code section 11343.4 (Register 2007, No. 34).
26. Amendment filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
27. Redesignation and amendment of former subsection (k) as new subsection (k)(1), new subsections (k)(2)-(3) and (n)(4) and amendment of list of incorporated standards and Note filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
28. Amendment of subsection (v), including redesignation and amendment of portion of former subsection (v) as new subsection (v)(1), new subsections (v)(2)-(v)(3)(D)6. and amendment of list of incorporated standards filed 9-1-2010; operative 1-1-2011 (Register 2010, No. 36).
29. Amendment of subsection (l), new subsections (l)(1)-(2), amendment of subsections (w)(1) and (w)(2), new subsections (w)(1)(A)-(D) and (w)(2)(A)-(B) and amendment of list of incorporated documents to update revision date of 10 CFR 430.23 filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).
30. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).
31. Amendment of subsection (i), new subsections (i)(1)-(2), amendment of list of incorporated documents and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5-15-2015 (Register 2015, No. 20).
32. New subsections (h)(2)-(h)(2)(C), subsection renumbering, amendment of subsection (i)(1), new subsection (i)(2), subsection renumbering and amendment of list of incorporated documents filed 8-20-2015; operative 8-20-2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).
33. New subsections (h)(5)-(6) and amendment of subsection (i)(3) filed 2-10-2016; operative 2-10-2016. Exempt from OAL review pursuant to Governor's Executive Order B-29-15, issued 4-1-2015 (Register 2016, No. 7).
34. Amendment of subsections (a) and (c), new subsections (c)(4)-(5), amendment of subsections (d), (f)(1) and (j), new subsections (j)(3)-(j)(3)(D) and amendment of subsections (o), (p) and (w)(2)(B) filed 6-30-2016; operative 7-1-2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).
35. Amendment of subsections (k)(2) and (k)(4), including new table K-1, and list of documents incorporated by reference filed 11-1-2016; operative 1-1-2017 (Register 2016, No. 45).
36. Amendment of subsections (v) and (v)(2)-(3), new subsections (v)(4)-(v)(5)(I) and amendment of list of incorporated documents filed 8-22-2017; operative 10-1-2017 (Register 2017, No. 34).
37. Change without regulatory effect amending Table D-1 and list of incorporated documents filed 9-11-2017 pursuant to section 100, title 1, California Code of Regulations (Register 2017, No. 37).
38. Adoption and amendment of subsections within subsection (g)(2) and amendment of list of incorporated documents filed 7-19-2018; operative 10-1-2019 (Register 2018, No. 29).
39. Amendment filed 9-26-2018; operative 10-1-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).
40. Editorial correction of subsection (a)(4) (Register 2018, No. 45).
41. Change without regulatory effect amending footnote to Table K-1, amending Table R-1 and amending list of documents incorporated by reference filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).
42. Amendment of subsection (s)(3) and list of documents incorporated by reference filed 6-10-2019; operative 6-10-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).
43. New subsections (x)-(x)(1)(A), amendment of list of documents incorporated by reference and amendment of Note filed 10-7-2019; operative 10-1-2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).
44. Amendment of subsection (k)(1), repealer of subsection (k)(2), subsection renumbering, amendment of newly designated subsections (k)(2)-(3), new subsection (k)(4), amendment of Table K-1 and subsection (k)(5) and amendment of list of documents incorporated by reference filed 12-24-2019; operative 1-1-2020 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 52).
45. Amendment of subsection (g), repealer of subsections (g)(3)-(g)(3)(D), subsection renumbering, amendment of newly designated subsection (g)(3), new subsections (g)(3)(A)-(g)(3)(C)2. and amendment of list of documents incorporated by reference filed 9-21-2020; operative 1-1-2021 (Register 2020, No. 39). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-66-20.
46. New subsections (v)(4)(J)-(v)(4)(K)4. filed 2-3-2021; operative 12-9-2021 pursuant to Government Code section 11343.4(b)(1) and Public Resources Code section 25402(c)(1) (Register 2021, No. 6).
47. Amendment of subsections (a)(4), (g)(2)(C), (k)(4) and (l), repealer of subsections (l)(1)-(2), amendment of subsections (n)(4)(A) and (w)(2)(D) and amendment of list of documents incorporated by reference filed 3-16-2021; operative 3-16-2021 pursuant to Government Code section 11343.4(b)(3) (Register 2021, No. 12). (Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20.)
48. Change without regulatory effect amending subsections (g)(2)(B)3.-4. and (g)(2)(C) and repealer of subsection (g)(4) filed 7-12-2021 pursuant to section 100, title 1, California Code of Regulations (Register 2021, No. 29).
49. Repealer of subsections (g)(2)(A)-(B), new subsection (g)(2)(A), redesignation and amendment of former subsection (g)(2)(C) as subsection (g)(2)(B) and amendment of list of documents incorporated by reference filed 9-8-2021; operative 1-1-2022 (Register 2021, No. 37).
50. Editorial correction removing duplicate subsection (v)(4) (Register 2022, No. 43).
51. Amendment of subsection (d), redesignation of portion of former subsection (d) as subsection (d)(1), amendment of Table D-3 heading, new subsections (d)(2)-(d)(2)(A), and amendment of list of documents incorporated by reference filed 1-17-2023; operative 11-16-2023 (Register 2023, No. 3).
52. Amendment of subsection (c)(3), including new subsections (c)(3)(A) and (c)(3)(B) and amendment of Table C-2, and amendment of list of documents incorporated by reference filed 4-7-2023; operative 7-1-2024 (Register 2023, No. 14).
53. Repealer of subsections (n)(4)-(n)(4)(B) and amendment of list of documents incorporated by reference filed 4-25-2023; operative 4-25-2023 pursuant to Government Code section 11343.4(b)(3) (Register 2023, No. 17).
54. Amendment filed 7-18-2024; operative 7-18-2024 pursuant to Government Code section 11343.4(b)(3) (Register 2024, No. 29).
55. Change without regulatory effect amending section filed 6-12-2025 pursuant to section 100, title 1, California Code of Regulations (Register 2025, No. 33).