Cal. Code Regs. tit. 19, § 999
(a) General.
(b) Steel Mortars.
(3) The inside length of steel mortars shall meet the minimum specifications set forth below:
Shell Size
Inside Length
1.99 inches or less
8 inches
2 inches
13 inches
2 ½ inches
13 inches
3 inches
15 inches
4 inches
20 inches
5 inches
25 inches
6 inches
30 inches
7 inches
32 inches
8 inches
32 inches
10 inches
40 inches
12 inches
40 inches
16 inches
64 inches
24 inches
96 inches
(c) Paper Mortars.
(1) Reusable paper mortars shall be of spiral or convolute wound kraft paper or chipboard, and shall meet the minimum specifications set forth below:
Shell Size
Wall Thickness
Inside Length
Base Plug*
Less than
2 inches
⅛ inch
8 inches
1 inch
2 inches
¼ inch
13 inches
2 inches
2 ½ inches
⅜ inch
13 inches
3 inches
3 inches
⅜ inch
15 inches
3 inches
4 inches
½ inch
20 inches
3 inches
5 inches
½ inch
25 inches
4 inches
6 inches
½ inch
30 inches
4 inches
7 inches
¾ inch
32 inches
4 inches
8 inches
¾ inch
32 inches
4 inches
* Sizes for base plugs are nominal.
(d) HDPE Mortars. High Density Polyethylene (HDPE) mortars shall meet the minimum specifications set forth below:
Shell Size
Wall Thickness
Inside Length
Base Plug*
Less than 2″
⅛ inch
10 inches
1 inch
2 inches
¼ inch
13 inches
2 inches
2 ½ inches
¼ inch
13 inches
3 inches
3 inches
¼ inch
15 inches
3 inches
4 inches
¼ inch
20 inches
3 inches
5 inches
¼ inch
25 inches
4 inches
6 inches
⅜ inch
30 inches
4 inches
7 inches
⅜ inch
32 inches
4 inches
8 inches
⅜ inch
32 inches
6 inches
* Base plug sizes are nominal.
HDPE Mortars shall not be reloaded for a period of at least one (1) hour after use. All base plugs for HDPE mortars shall be wooden, and securely glued, as well as nailed, screwed, or bolted to the base of the mortar. Base plugs shall be discarded and replaced when damaged. Minor cracks and checks are acceptable.
(e) Other Materials. Recognizing that new materials for the construction of mortars may be developed, such materials may be used when specifically approved by the State Fire Marshal. Persons wishing to use material not specifically covered in this section shall submit the material in an amount sufficient for testing to the State Fire Marshal for determination of its safety and its inclusion in this section.
Note: For illustrations of typical mortar racks, troughs and drums, see Diagrams A, B and C following section 1002.
Note: Authority cited: Section 12552, Health and Safety Code. Reference: Section 12552, Health and Safety Code.
1. Repealer of former section 999 and new section filed 6-26-91 as an emergency; operative 6-26-91 (Register 91, No. 48). A Certificate of Compliance must be transmitted to OAL by 10-24-91 or emergency language will be repealed by operation of law on the following day.
2. Emergency language repealed by operation of law. Repealer of former section 999 and new section filed 4-14-92; operative 5-14-92 (Register 92, No. 21).