Cal. Code Regs. tit. 13, § 2854
(a) For MY 2018 and later, SIMW using SIME less than or equal to 30 kW must comply with the evaporative emissions standards and test procedures in 40 C.F.R., § 1060 (October 8, 2008), as incorporated by reference herein and specified in the Table below.
Evaporative Emissions Harmonized Design Standards for ≤ 30 kW SIMW Table
Model Year (MY) Effective Date
Fuel Hose Permeation (grams/m2/day ROG1)
Fuel Tank (grams/m2/day ROG1)
Diurnal (grams/gallon/day HC2)
Fuel Injection (grams HC2/hour)
2018 and Later
15.0
1.53
0.4
None
Test Procedure
40 C.F.R., § 1060.515
40 C.F.R., § 1060.520
40 C.F.R., § 1060.525
None
1 Reactive Organic Gases (ROG).
2 Hydrocarbon (HC).
3 As an alternative, component manufacturers can certify at 2.5 grams/m2/day at 40°C.
Note: Authority cited: Sections 39600, 39601 and 43013, Health and Safety Code. Reference: Section 43013, Health and Safety Code.
1. New section filed 2-8-2016; operative 4-1-2016 (Register 2016, No. 7).