Cal. Code Regs. tit. 13, § 817
(a) Steady-burning Warning Lamps. Steady-burning warning lamps, and flashing warning lamps which alternate between on and off by electrically controlling the current supplied to the lamp, shall meet the requirements in Table I. The photometric output of flashing lamps shall be reported only while the lamp is on. Warning lamp units shall be aimed for this test so the maximum intensity is on the H-V axis. Warning lamp assemblies shall be mounted for this test in accordance with Section 657.
TABLE I. MINIMUM CANDELA FOR STEADY-BURNING WARNING LAMPS AND FLASHING WARNING LAMPS WHICH ALTERNATE BETWEEN ON AND OFF BY ELECTRICALLY CONTROLLING THE CURRENT
Test point coordinates
Class A Lamps
Class B Lamps
Class C Lamps
Class D Lamps
Vertical
Horizontal
Red
Red
Yellow
Blue
Red
Yellow
Blue
Red
5L
15
20
50
10
10
25
5
5
10U
V
15
50
125
25
25
65
13
12
5R
15
20
50
10
10
25
5
5
20L
10
20
50
10
150
375
75
5
10L
25
50
125
25
300
750
150
12
5L
50
100
250
50
300
750
150
25
5U
V
80
150
375
75
300
750
150
40
5R
50
100
250
50
300
750
150
25
10R
25
50
125
25
300
750
150
12
20R
10
20
50
10
150
375
75
5
30L
--
--
--
--
30
75
15
--
20L
30
30
75
15
180
450
90
10
10L
300
75
190
38
400
1,000
200
15
5L
500
200
500
100
500
1,250
250
500
2 1/2L
2,000
--
--
--
--
--
--
1,500
H
V
3,000
300
750
150
600
1,500
300
3,000
2 1/2R
2,000
--
--
--
--
--
--
1,500
5R
500
200
500
100
500
1,250
250
500
10R
300
75
190
38
400
1,000
200
15
20R
30
30
75
15
180
450
90
10
30R
--
--
--
--
30
75
15
--
30L
--
--
--
--
30
75
15
--
20L
10
20
50
10
200
500
100
5
10L
25
50
125
25
300
750
150
12
5L
50
100
250
50
450
1,100
275
25
5D
V
80
150
375
75
450
1,100
275
40
5R
50
100
250
50
450
1,100
275
25
10R
25
50
125
25
300
750
150
12
20R
10
20
50
10
200
500
100
5
30R
--
--
--
--
30
75
15
--
5L
15
20
50
10
40
100
20
5
10D
V
15
50
125
25
40
100
20
12
5R
15
20
50
10
40
100
20
5
Note: Maximum anywhere in yellow shall not exceed 4,000 cd over any area larger than that generated by a radius rotated 0.25 deg.
(b) Revolving Warning Lamps. Revolving warning lamps shall meet the requirements in either Table II or Table IV with the required test voltage applied to the input terminals of the complete assembly. A revolving lamp that is designed to project a signal throughout a 360 degree horizontal angle shall be tested with the lamp assembly turned about its vertical axis to the location where the maximum candela reading from the optical unit is reduced the most by any variations in density or shape of the transparent cover or by obstructions in the lamp assembly. A revolving warning lamp that does not project light through a 360 degree horizontal angle shall comply photometrically about those axes straight to the front, sides, and rear of a vehicle to which the lamp is designed to provide a warning signal. As the lamp rotates, the full projected area of the reflector of each light unit shall be visible along the beam axis as the center of the beam moves from 20 degrees left to 20 degrees right of the device axis.
TABLE II. MINIMUM CANDELA FOR REVOLVING WARNING LAMPS
Test point coordinates
Vertical
Horizontal
Red
Yellow
Blue
7.5U
V
50
130
25
5U
V
500
1,250
250
2.5U
V
3,000
7,500
1,500
H
V
5,000
12,500
2,500
2.5D
V
3,000
7,500
1,500
5D
V
500
1,250
250
7.5D
V
50
130
25
(c) Oscillating Warning Lamps. Oscillating warning lamps shall meet the requirements in Table III with the required test voltage applied to the input terminals of the complete assembly.
TABLE III. MINIMUM CANDELA FOR OSCILLATING WARNING LAMPS
Test point coordinates
Vertical
Horizontal
Red
Yellow
Blue
7.5U
V
50
130
25
5U
V
500
1,250
250
2.5U
V
3,000
7,500
1,500
20L
500
1,250
250
10L
1,200
3,000
600
5L
3,300
8,250
1,650
H
V
5,000
12,500
2,500
5R
3,300
8,250
1,650
10R
1,200
3,000
600
20R
500
1,250
250
2.5D
V
3,000
7,500
1,500
5D
V
500
1,250
250
7.5D
V
50
130
25
(f) Removal from Service. Any warning lamp assembly which noticeably fails to function properly shall be removed from service. Warning lamp assemblies which utilize multiple light sources shall be removed from service if any individual light source fails to function properly.
TABLE IV. MINIMUM CANDELA-SECONDS FOR GASEOUS DISCHARGE WARNING LAMPS
Test point coordinates
Vertical
Horizontal
Red
Yellow
Blue
7.5U
V
5
12
3
5U
V
10
25
5
2.5U
V
30
75
15
20L
5
12
3
10L
12
30
6
5L
33
82
17
H
V
50
125
25
5R
33
82
17
10R
12
30
6
20R
5
12
3
2.5D
V
30
75
15
5D
V
10
25
5
7.5D
V
5
12
3
Note: The L and R test points do not apply to 360-deg lamps.
The luminous intensity of warning lamps tested as specified in Article 4 of this subchapter, with a reaim tolerance of ± 0.5 degree vertical and ± 1.0 degree horizontal allowed at each test point, shall be as follows:
Note: Authority cited: Section 26103, Vehicle Code. Reference: Sections 24012 and 26103, Vehicle Code.
1. Amendment filed 11-25-2002; operative 12-25-2002 (Register 2002, No. 48).