1. Toilets and hand-washing sinks are available to enrolled children in a facility as follows:
- a. At least one flush toilet and one hand-washing sink for 10 or fewer children,
- b. At least two flush toilets and two hand-washing sinks for 11 to 25 children, and
- c. At least one flush toilet and one hand-washing sink for each additional 20 children;
- 2. A hand-washing sink required in R9-5-503(A)(2) or subsection (2) provides running water with a drain connected to a sanitary sewer as defined in A.R.S. § 45-101;
- 3. A glass mirror, window, or other glass surface that is located within 36 inches of the floor is made of safety glass that has been manufactured, fabricated, or treated to prevent the glass from shattering or flying when struck or broken, or is shielded by a barrier to prevent impact by or physical injury to an enrolled child.
A licensee shall comply with the following physical plant requirements, as applicable:
Historical Note
New Section made by final rulemaking at 31 A.A.R. 2015 (June 27, 2025), effective August 3, 2025 (Supp. 25-2).