- A. At least one ladder shall be provided in the deep area of a public or semipublic swimming pool. If the width of the deep area of a swimming pool is greater than 20 feet, then one ladders shall be located on opposite sides of the deep area.
- B. A swimming pool or spa ladder shall be equipped with two handrails.
- C. All treads on ladders shall have slip-resistant surfaces.
- D. Ladder treads shall have a minimum horizontal depth of 1 1/2 inches. The distance between ladder treads shall range from a minimum of 7 inches to a maximum of 12 inches.
- E. Below the waterline, there shall be a clearance of not more than 6 inches and not less than 3 inches between any ladder tread edge and the wall as measured from the side of the tread closest to the wall.
Historical Note
Adopted effective February 19, 1998 (Supp. 98-1).