(a) Test method for leak detection:
- (1) Within four (4) hours prior to monitoring, the organic vapor analyzer or combustible gas detector shall be suitably calibrated in a manner and with the gas specified by the manufacturer for twenty percent (20%) of the lower explosive limit response, or calibrated with methane for a ten thousand parts per million (10,000 ppm) response;
- (2) The probe inlet shall be two and one-half centimeters (2.5 cm) or less from the potential leak source when searching for leaks; and
(3)
- (A) The highest detector reading and location for each incident of detected leakage shall be recorded, along with the date, time, and name of the person performing the testing.
- (B) If no gasoline vapor is detected, that fact shall be recorded.