(a) When the EGS main door is opened, the game shall:
- (1) Cease play;
- (2) Enter an error condition;
- (3) Display an appropriate error message;
- (4) Disable bill acceptance; and
(5) Either:
- (A) Sound an alarm;
- (B) Illuminate the tower light; or
- (C) Both.
- (b) When the EGS main door is closed, the game shall return to its original state and display an appropriate error message, until the next game has ended.
(c) The software shall be able to detect any meter access to the following doors or secure areas:
- (1) All external doors;
- (2) Drop box door; and
- (3) Bill acceptor door.