Harvested marijuana and any product processed from harvested marijuana shall be stored in one (1) of the following types of secured areas:
(1)
- (A) A safe or steel cabinet.
(B) Which safe or steel cabinet shall have the following specification or the equivalent:
- (i) Thirty (30) man-minutes against surreptitious entry;
- (ii) Ten (10) man-minutes against forced entry;
- (iii) Twenty (20) man-hours against lock manipulation; and
- (iv) Twenty (20) man-hours against radiological techniques;
- (C) If it weighs less than seven hundred fifty pounds (750 lbs.), is bolted or cemented to the floor or wall in such a way that it cannot be readily removed; and
- (D) If necessary, depending upon the quantities and type of controlled substances stored, is equipped with an alarm system as described in 20 CAR § 810-404; or
(2)
- (A) A vault.
- (B) The walls, floors, and ceilings of which vault are constructed of at least eight inches (8”) of reinforced concrete or other substantial masonry, reinforced vertically and horizontally with one-half inch (½”) steel rods tied six inches (6”) on center, or the structural equivalent to such reinforced walls, floors, and ceilings.
(C) The door and frame unit of which vault shall conform to the following specification or the equivalent:
- (i) Thirty (30) man-minutes against surreptitious entry;
- (ii) Ten (10) man-minutes against forced entry;
- (iii) Twenty (20) man-hours against lock manipulation; and
- (iv) Twenty (20) man-hours against radiological techniques.
- (D) Which vault, if operations require it to remain open for frequent access, is equipped with a “day-gate” which is self-closing and self-locking, or the equivalent, for use during the hours of operation in which the vault door is open.
- (E) The walls or perimeter of which vault are equipped with an alarm system as described in 20 CAR § 810-404.
- (F) The door of which vault is equipped with contact switches.
(G) Which vault has one (1) of the following:
- (i) Complete electrical lacing of the walls, floor, and ceilings;
- (ii) Sensitive ultrasonic equipment within the vault;
- (iii) A sensitive sound accumulator system; or
- (iv) Other such device designed to detect illegal entry.