- (a) Automatic flushing controls shall be required for all drip systems.
- (b) The flush valve shall be a solenoid or a pressure/flow-compensating valve.
- (c) Manual flushing valves may be installed in the field flush line.
- (d) Manually operated valves may be standard ball or gate valves.
- (e) The flush valve shall be fully opened during a flush cycle regardless of the valve type.
- (f) The field flushing velocity shall be in accordance with the drip tubing or system manufacturer's recommendations.
- (g) The minimum field flushing velocity shall not be less than five-tenths feet (0.5’) per second.