The plumbing plans submitted pursuant to Rule 535-X-11-.07 of this chapter must:
- (a) Provide plan and riser diagram of the plumbing layout showing size of piping, fittings, traps and vents, cleanouts and valves, etc., for gas, water, drainage, waste, and vent systems.
- (b) Indicate plumbing materials to be used and approvals, as well as for fired appliances and equipment. Show make, model, rating/capacity.
- (c) Indicate make and model of safety controls and their location, such as for water heaters, etc.
- (d) Indicate how piping is to be supported and intervals of support.
- (e) Indicate how piping, valves, and risers are to be supported such as by backing, as necessary.
- (f) Show location of flues and vents above roofs and required clearances, such as from air intakes, and other vents and flues, etc.
- (g) Indicate method of testing.
Author: Harold A. Hendrix
Statutory Authority: Code of Ala. 1975, §§24-4A-3, 24-6-4.
History: Filed February 6, 1990.