(a) A registrant of an x-ray machine used in industrial radiography shall establish operating and emergency procedures that includes instructions in the following:
- (1) the handling and use of the x-ray machine in a manner that ensures that an individual is not exposed to doses in excess of the limits established in 7 AAC 18.210 - 7 AAC 18.250;
- (2) methods for controlling access to radiographic areas;
- (3) methods and occasions for conducting ionizing radiation surveys;
- (4) methods and occasions for locking and securing the x-ray machines;
- (5) personnel monitoring and the use of personnel monitoring equipment;
- (6) transportation to field locations;
- (7) the procedure for notifying proper persons in the event of an accident; and
- (8) maintenance of records.
- (b) A registrant of an x-ray machine used in industrial radiography shall assure that an individual who operates the machine as a radiographer has received a copy of, been instructed in, and demonstrated an understanding of operating and emergency procedures established in accordance with this section.
(Eff. 4/9/2009, Register 190)
Authority: AS 18.60.475, AS 18.60.485