The operator of a food establishment shall ensure that
(1) permanently installed artificial light sources provide
- (A) at least 50 foot candles of light, evenly distributed, measured 30 inches from the floor, on preparation, processing, and warewashing surfaces and equipment; and
- (B) at least 20 foot candles of light, evenly distributed, measured 30 inches from the floor, in other areas; dining areas must meet this standard only during cleaning activities; and
(2) protective shielding is provided for breakable artificial lighting fixtures located
- (A) over equipment used to hold or display food;
- (B) in walk-in refrigerators or freezers;
- (C) over any area where food or food-contact surfaces are exposed such as preparation, service, and display areas; and
- (D) over equipment and areas where utensils and equipment are cleaned or stored.
(Eff. 5/18/97, Register 142; readopt 12/19/99, Register 152)