(a) The owner or operator of a school or shop subject to 18 AAC 23.010(b) shall ensure that each non-single-use, non-disposable instrument that is required in this chapter to be cleaned and sterilized is
(1) cleaned either
(A) by hand by
- (i) rinsing the instrument in a cold water rinse to remove visible soil;
- (ii) soaking the instrument in an enzyme pre-soak before cleaning;
- (iii) using warm water and an appropriate detergent;
- (iv) rinsing the item thoroughly; and
- (v) inspecting the instrument carefully for cleanliness and damage; or
(B) mechanically by
- (i) rinsing the instrument in a cold water rinse to remove visible soil;
- (ii) soaking the instrument in an enzyme pre-soak before cleaning; and
- (iii) placing the instrument directly into an ultrasonic cleaner for a 10-minute cycle or as recommended by the manufacturer;
- (2) dried after cleaning and placed in a sterilization pouch that has either a sterilizer indicator or internal temperature indicator; and
- (3) sterilized in a sterilizer if a package seal on a sterilization pouch containing an instrument has been broken, that instrument may not be used until it is sterilized again.
- (b) If a school or shop uses only single-use, disposable, sterile instruments and products, sterilization in a sterilizer is not required.
(c) The owner or operator shall demonstrate that a sterilizer used in the school or shop is capable of attaining sterilization through a spore destruction test performed every 30 days. These spore destruction tests must
- (1) be conducted using a commercially prepared biological sterilization process indicator to culture specifically for Bacillus stearothermophilus for steam sterilizers or Bacillus subtilis for dry heat sterilizers; and
(2) be verified
- (A) through a laboratory independent of the school or shop; or
- (B) within the school or shop in accordance with the biological sterilization process indicator's manufacturer's instructions.
- (d) If a laboratory independent of the school or shop is used to conduct a spore destruction test, the owner or operator must obtain results of that test within 24 hours after performing the test.
(e) If the results of a spore destruction test are positive for the presence of a spore described in (c)(1) of this section, the owner or operator shall ensure that
- (1) any instrument processed in that sterilizer is not used on clients until the instrument is resterilized using the procedures in (a) of this section before use; and
- (2) the sterilizer is not used until a negative test result is achieved.
(Eff. 12/1/2002, Register 164)
Authority: AS 08.13.030, AS 08.13.120, AS 08.13.210, AS 44.46.020