118 Va. 482 | Va. | 1916
delivered the opinion of the court.
The right of the defendant in error, who was the plaintiff below, to recover damages for the death of her intestate was rested upon the grounds stated in a declaration containing four counts. The court sustained a demurrer to the fourth count, and, without objection, instructed the jury that there was no' evidence to. sustain the second count;- so that the case was tried on the first and third counts.
(1) The first count alleges that the stay-holts supporting the crown-sheet were made of defective material, that the workmanship was faulty; and that they had been weakened and rendered unsafe by previously having been burned. (2) And the third count alleges that the glass water-gauge was out of repair and in an unsafe condition; the valves therein being stopped up with lime, trash or other deposits, and improperly registered the quantity of water in the boiler. Both these counts are founded on an act of Congress approved February 17,
The following is an outline narrative of the salient facts: The engine which is the subject of investigation was one of ten engines built for the defendant by the Baldwin Locomotive Works, which is one of the largest and most reliable manufactories of engines in the United States. At the time of the accident the engine was practically new, having been used for the first time in May, 1912. It was constructed with great care, both with respect to material and workmanship; and, during the course of construction, in every detail, was subjected to rigid inspection by experienced inspectors detailed by the defendant for that service. The specification called for a crown-sheet for the engine with a margin of safety of 13.3 under steam pressure of 200 pounds. The engine was being operated with a steam pressure of 185 pounds, and, properly handled was capable of withstanding a pressure of about sixteen times the pressure to which it was subjected at the time of the accident. The inspectors tested the tensil strength of the materials used in the crown-sheet and stay-bolts before they were put in the engine, and found them of the required strength. After the engine had been completed, the boiler was thoroughly tested with water and steam, and likewise proved satisfactory. It was then washed out with soda and cleansed of grease, oil and other foreign substances used in and which collected during the course of construction. The engine was practically in the control of plaintiff’s intestate and run by him during the entire time it was in operation. On November 11, 1912, three days prior to the accident, it was inspected by government inspectors under the act of Congress, which inspection showed that the engine, boiler and appurtenances were in perfect condition. From the time of that inspection until the explosion, the engine was exclusively operated by
It thus appears from the undisputed evidence that at 9:30 p. m., the time of departure for Princeton, just one hour before the explosion, the defendant had complied with every requirement of the boiler act, and the locomotive engine, boiler and appurtenances measured up to statutory standard.
After the explosion the engine was hauled to Princeton by another engine. The cab was boxed up as required by the boiler act, and the engine, boiler and appurtenances remained in the condition in which they were found after the explosion until November 16th and 17th, when they were inspected by two government inspectors sent out for that purpose by the Interstate Commerce Commission. These officials made their report and also testified at the trial, and proved that apart from
Tt is insisted on behalf of the plaintiff that in legal intendment the boiler act is not to be distinguished from the original safety appliance act of March, 1898, and amendments, and the employers’ liability act of 1908. These latter acts have been construed by the Supreme Court of the United States to impose upon the carrier the absolute duty to provide and maintain proper couplers and other appliances therein mentioned at all times and under all circumstances. St. L., F. M, & S. Ry. Co. v. Taylor, 210 U. S. 281, 28 Supt. Ct. 616, 52
It will be observed that the safety appliances considered ■ in •’ the foregoing and analogous cases, either work automatically, as couplers which operate by impact, or else are simple contri-'’ vanees, as draw-bars and the like, which are the objects rather' than the subjects of action, and when once placed in position remain intact and discharge their, functions until changed by some active agency. A locomotive engine, on the other hand, however perfect its condition may be, in its operation calls, for the continuous exercise of a high degree of skill and experience, and the constant supervision and attention. of the engineer. In other words, the two classes of instrumentalities. are so inherently diverse in character and use that rules which, would be reasonable and appropriate in respect to the one class, would be impossible of practical application to the other. The, avowed object of the boiler act, .it is true, is to promote the safety of employees and travelers, and to that end section 2 declares that from and after July 1, 1911, it shall be unlawful' for any common carreir to use any locomotive engine propelled by steam power in moving interstate hr foreign traffic unless the boiler and appurtenances thereof are. in proper condition and safe to operate in the service to which the same is put, that the same may be employed in the active service of such carrier in moving traffic without unnecessary peril to life and limb. When, therefore, the carrier has discharged his statutory dirty', to the engineer by turning over to him a locomotive engine and, boiler and appurtenances in proper condition and sáfe. to operate, it is not answerable to the engineer as an insurer of htis‘ safety throughout the run; and in. order, for his. personal’ representative to maintain an action for his . death caused by''
The occupants of the cab at the time of the accident were the engineer, Andrews, a brakeman, Lucas, and the fireman, Jerre Walton. The two former were killed, and the plaintiff sought to prove by Walton that the explosion resulted from defects in the crown-sheet or stay-bolts which existed prior to the accident. This witness admittedly had no familiarity with that type of engine, that being his first trip on an engine of that class; and, not to mention distractions incident to the discharge of his "duties as fireman his only opportunity for acquiring information concerning the engine, boiler and appurtenances covered an hour in time and eighteen miles in distance. He never saw the crown-sheet until after the explosion, and did not know the height of the firebox door, or what position he would have to assume to see the crown-sheet, or whether there was a brick arch inside the engine which would obstruct the view of the crown-sheet. Nevertheless, he was permitted to express the opinion that if the crown-sheet had been burnt on that trip and made red hot there would have been a different glow in the fire-box. The opinion evidence of this witness was altogether speculative and plainly inadmissible. VirginiaCarolina Chem. Co. v. Knight, 106 Va. 674-677, 56 S. E. 725; Norfolk & Portsmouth Traction Co. v. Ellington, 108 Va. 245, 61 S. E. 779, 17 L. R. A. (N. S.) 117.
The same is true of the evidence of the witness, Eichardson, on the same point. Walton also testified that the injector was working properly and supplying water to the boiler, basing his opinion on the sound it gave forth; yet he admitted that he was without experience as to injectors of that sort. He testified that the injectors and pipes leading from them into the boiler were located inside the cab, when in fact they were on the outside. Other witnesses for plaintiff testified that it required familiarity with, this class of engine and ejectors for
It was also in evidence that though the injector was in good order, it would not automatically supply the*engine with water, but to accomplish that result it was necessary for the engineer to properly adjust the valves introducing water and steam into the injector, and unless that was done the water would not be forced into the boiler but would escape througli the waste pipe; and, furthermore, if that precaution was neglected, that the interval of time which elapsed between Singers’ tank and the point of accident was sufficient for the crown-sheet to become exposed from lack of water, in which event the explosion would have been inevitable.
We shall not extend this opinion by entering upon a detailed analysis of the evidence of expert witnesses for the plaintiff. The trial court allowed great latitude in their examination, and numerous theories were advanced as to what possibly might have caused the accident. However, it is enough to say that a painstaking examination of this evidence shows that the opinion of the witnesses were neither founded upon facts within their own knowledge, or established by other evidence in the case. Hence, their conclusions were matters of speculation, and possessed no evidential value. Such statements violate the fundamental principle (so often accentuated in opinions of this court) that an inference cannot be drawn from a presumption. A verdict resting upon such foundation is not the fruit of evidence, but of conjecture, and cannot be upheld.
These essential rules of evidence were not- observed in the trial of this case, and there is no criterion by which to estimate the influence that this inadmissible matter may have exerted on the minds of the jury.
We are of opinion that the body of the evidence, viewed from-the standpoint of a demurrer to the evidence, shows that on the night of November 14, 1912, when the engine was turned over to plaintiff’s intestate, the boiler and appurtenances were in proper condition and safe to operate in the service to which the same were to be put in moving traffic without unnecessary peril to life and limb, within the-true intent and meaning of the act of Congress. When the explosion occurred, the locomotive engine and boiler and appurtenances were in the exclusive custody and control of the engineer and were being operated by him. In these circumstances, upon settled principles, the mere happening of the accident did not per se cast upon the defendant the imputation of negligence; but to warrant a recovery the burden rested upon the plaintiff to prove that the defendant had been guilty of the negligence alleged in the declaration.
Nor is this a case, as was pressed in argument, where the negligence of the engineer should go to mitigate the damages, but not to bar the right of action. The evidence tends to show that the negligence of plaintiff’s intestate was the sole cause, not the contributing cause, of his death, and, therefore the rule invoked under the employers’ liability act has no application.
. We are further of opinion that the plaintiff has not successfully borne the burden of proof thus resting upon him, and that-the evidence was not sufficient to warrant the verdict.
This view of the case is controlling and renders it unnecessary to discuss the subordinate assignments of error.
The judgment complained of must he reversed, the verdict of the jury set aside, and the case remanded for a new trial.
Reversed.