Appellants Michelle and Bob Stegall appeal from the order of the superior court granting summary judgment to appellee Central Georgia Electric Membership Corporation (EMC). This is a suit for money damages for the full value of the life of apрellants’ six-month-old child who in August 1994 was electrocuted in the improperly grounded mobile home which appellants rented; electricity to the home was being provided by EMC.
In September 1993, appellants Michelle and Robert Stegall rented and moved into a mоbile home owned by and located in the trailer park of defendant David Buice. Within a couple of weeks thereafter, appellants noticed they were receiving an electric shock of a “tingling” nature whenever, for example, they simultanеously touched two pieces of metal in or on the mobile home. Appellant Michelle Stegall reported this situation repeatedly to defendant Buice to no avail. On June 1, 1994, she telephonically reported the matter to an EMC office. Thе EMC employee who received the call sent a trained EMC service technician, Donald Yost, to the premises. Yost was informed of the circumstances under which appellees were receiving shocks both inside and when entering the mobile home. Yоst tested several areas of the mobile home and determined that the voltage reading being obtained ranged from 95 volts to 105 volts. Yost considered this a hazardous condition which had the potential to injure seriously or kill someone. Yost conducted further tеsts and concluded that the problem originated either from the main inside the mobile home or one of the circuits that feeds the mobile home. He continued his inspection until he found that shutting off one particular circuit breaker caused the voltage rеading to register zero. Monroe County does not have any governmental inspectors to whom *188 Yost could report the problem. While Yost did not report the problem directly to his supervisor, he followed normal procedure and filed his report with the EMC dispatcher for entry into the trouble log. Although he had the authority immediately to shut off the power to the mobile home, or to cause a notice letter to be written by EMC’s engineering department stating electricity would be cut off if the deficiency was not corrected within a certain time period, he did not do so. Rather, Yost personally informed Michelle Stegall of how dangerous the situation was, told her that his friend had been killed by that same level of voltage, and advised her not to turn the circuit breaker back оn until someone had checked and repaired it. Yost is not an electrician and is not licensed to make such repairs. Appellant Michelle Stegall discussed the situation with Yost and caused him to believe she was going to call David Buice and tell him that someone needed to look at the circuit which had been cut off. She also caused him to believe she had called EMC as a last resort, although she did not tell him she had repeatedly called David Buice previously to no avail. Although he could havе done so, Yost made no re-inspection of the premises to determine if the problem had been corrected, and neither did he request that someone else in EMC make a follow-up call; such procedures are not required and he has nevеr done this in the past.
EMC policy no. 305 pertinently provides: “Each member is responsible for all premises receiving electrical service to become and remain wired in accordance with the specifications and requirements of the Central Georgia EMC, the National Electrical Code, the National Electrical Safety Code, and any requirements of local government agencies having jurisdiction over the installation of electrical wiring. ... In the event of a known hazardous condition or potentially hazardous condition because of a violation of requirements, electrical service will not be connected until the condition is corrected. In the event service is being received, the member will be notified by certified mail or personal delivery, with copy to County or City Inspections Departments, if applicable, that if deficiencies are not corrected within a stated time, service may be discontinued. Employees noting unsafe conditions should notify their immediate supervisor whо will take appropriate action to follow up on circumstances. Responsibility: All Employees.” Yost identified and professed familiarity with EMC policy no. 305; however, it was his understanding that the policy did not apply to problems outside EMC’s area of responsibility, that is, it applies to conditions existing in EMC lines and equipment located outside the customer’s home.
Although he did not fix the circuit deficiency, Yost also testified that after he had turned off the circuit breaker he informed Michelle Stegall of the nature of the danger, infоrmed her that if the circuit *189 breaker was turned on before being fixed that lives would again be in danger, and advised her of the corrective action that needed to be taken. She appeared to understand the seriousness of the situation. Michelle Stegall stated in an affidavit that she did not understand the shock she was receiving could kill anyone; and, while Yost did tell her a friend of his had been killed by “120,” she did not understand the person had been killed under conditions similar to those in her trailer or that “120 had anything to do with our trailer.” As long as thе breaker was switched off, there no longer existed a life-threatening condition in the mobile home. In fact, Michelle Stegall confirmed that she received no electrical shocks while the breaker was off.
Michelle Stegall called Buice who initiаlly sent a man named “Peanut” Price to the trailer. Michelle testified by way of deposition that the breaker had remained off since the visit of Yost until after Price arrived on the premises. Buice and Price replaced all the receptacles оn the identified circuit. Buice states that the defective circuit breaker was on when he initially arrived at the trailer. Michelle Ste-gall testified inter alia that the breaker was not on when Buice first arrived but she later turned it on after Price told her to do so and instruсted her she could keep it on; thus, the breaker was on when Buice returned to the trailer the next day. Buice testified by way of deposition that the electrical system seemed to be working properly after the receptacles were changed and at no time, either before or after the repairs, had he received a shock from the trailer. Michelle Stegall testified that within a day or two following the repairs she again received electrical shocks from touching objects in the premises; she called and reported the situation to Buice. She also testified that, although Yost had told her to keep the circuit off, Buice then told her she could turn it on because she needed air conditioning but to “stay away from the thing,” and that he would have it fixеd. Thereafter, she kept the circuit breaker on for two months, until the child was electrocuted. Buice admits he may have told her that she could turn on the circuit after the receptacles were changed; in any event, when he left the premises he knеw the circuit was on. Buice, however, asserts he never heard anything more about the situation from appellants until after their daughter was killed.
Following the repairs made by Buice and Price, no one ever called Yost or EMC to report that the deteсted problem still existed, until after the child was killed on August 9, 1994. Yost went back to the premises to assist the sheriff in his investigation; the circuit breaker was turned on and the same voltage problem originating from the same circuit occurred. The breaker was turned off, and onсe again the dangerous condition was abated. Appellants were still residing in the trailer at the time their depositions were taken, and appellant Michelle Stegall believed that the previously existing dan *190 gerous condition was no longer dangerous as Candy, an independent master electrician, had looked at the circuit breaker and had in some fashion “turned it off.”
Subsequent to the child’s death and at the request of the sheriff’s department, Candy examined the premises and opined that the child’s death oсcurred because the mobile home was not properly grounded; there was no ground wire attached to the ground bus inside the mobile home and there was no ground rod driven into the soil outside the home. This improper grounding violated the National Electric Sаfety Code. An EMC supervisor testified that under EMC policy if a serviceman goes to a premise and knows there is not a driven ground rod grounding the meter base, either he should not hook up the electric service or he should discontinue any existing service; however, it may not be known whether there exists a driven ground rod because specifications require the rod to be 18 inches underground. Candy drove a ground rod outside the trailer and connected the ground bus inside the service panel to the proper ground.
Appellants enumerate five errors. Held:
1. The applicable summary judgment standard is that of
Lau’s Corp. v. Haskins,
2. Pretermitting whеther EMC owed a duty of care to appellants and their deceased child and if so, whether they breached such duty (compare
Hatcher v. Ga. Power Co.,
“Exceрt in plain, palpable and undisputed cases where reasonable minds cannot differ as to the conclusions to be reached, questions of negligence, proximate cause, including the related issues of foreseeability, assumption of risk, lack of ordinary care for one’s own safety, lack of ordinary care in avoiding the consequences of another’s negligence, contributory and comparative negligence are for the jury.”
Wade v. Mitchell,
In view of the above holding, we decline to address each of appellants’ enumerations of error seriatim; a grant of summary judgment must be affirmed if it is right for any reason.
Malaga Mgmt. Co. v. John Deere Co.,
Judgment affirmed.