1986 Tax Ct. Memo LEXIS 481 | Tax Ct. | 1986
MEMORANDUM FINDINGS OF FACT AND OPINION
SCOTT,
Petitioners | Year Ending | Deficiency |
Morrison Cafeteria Company of | May 28, 1977 | $4,204.40 |
Columbia, South Carolina, Inc. | June 3, 1978 | 19,164.50 |
Morrison Cafeteria Company of | May 31, 1975 1 | 9,144.00 |
Jefferson Parish, Inc. | May 28, 1977 | 127,407.82 |
June 3, 1978 | 14,389.50 | |
Morrison Support Companies of | May 28, 1977 | 1,259.80 |
Georgia, Inc. | June 3, 1978 | 4,455.61 |
Morco Industries, Inc. | June 3, 1978 | 3,486.40 |
(Formerly Morrison Support | ||
Companies of Florida, Inc.) | ||
Morrison Food Services of | May 31, 1975 | 5,313.53 |
Virginia, Inc. | May 28, 1977 | 6,471.00 |
Morrison, Inc. | May 28, 1977 | 142,929.00 |
June 3, 1978 | 138,248.24 | |
Morrison Cafeteria Company of | May 28, 1977 | 4,140.40 |
Savannah, Inc. | June 3, 1978 | 3,653.00 |
Morrison Cafeteria of | May 28, 1977 | 14,273.20 |
Woodland Hills, Inc. | June 3, 1978 | 39,468.70 |
Morrison Incorporated of | May 28, 1977 | 7,874.18 |
Tennessee | June 3, 1978 | 28,075.00 |
Morrison Cafeteria, Inc. | May 28, 1977 | 158.60 |
June 3, 1978 | 13,521.71 |
Some of the issues raised by the pleadings have been disposed of by agreement of the parties, leaving for our decision only whether petitioners are entitled to investment taxs credits granted by section 38 2 for any or all of 19 categories of assets that were purchased and installed in cafeterias constructed by petitioners during the fiscal years ending May 28, 1977 and June 3, 1978, and a portion of the costs of the primary electrical distribution systems installed in their caeteria buildings during these years. 31986 Tax Ct. Memo LEXIS 481">*483
FINDINGS OF FACT
Some of the facts have been stipulated and are found accordingly.
Petitioners consist of Morrison, Inc., and nine related corporations. 4 The principal place of business of each petitioner was Mobile, Alabama, at the time the petition in this case was filed. Petitioners filed their original and amended Federal corporate income tax returns for the years in issue with the Internal Revenue Service Center, Atlanta, Georgia.
Petitioner, Morrison Inc., is the parent corporation1986 Tax Ct. Memo LEXIS 481">*484 of the remaining petitioners. During the years at issue, petitioners owned and operated several diverse businesses, but their primary business was the operation of public cafeterias. The corporation began in 1920 with the opening of the first cafeteria in Mobile, Alabama. The business has grown so that by May 1977 it included 101 cafeterias and by June 1978 included 117 cafeterias. Over the years Morrison Inc. has organized or acquired subsidiary corporations to provide food to the cafeterias, roast and grind coffee, manufacture cleaners and detergents, supply food service equipment, manufacture furniture and kitchen equipment, supply interior accessories and decorations, build cafeterias, provide insurance for cafeterias and provide advertising services. Petitioners offer in excess of 100 menu items to the public each day, including numerous items in the categories of appetizers, salads, soups, entrees, vegetables, fruits, breads, desserts and beverages. Petitioners receive volume shipments of food products, including raw food products such as dressed turkeys and chickens and frozen and fresh vegetables. Petitioners uncrate and unpackage the food products and prepare them for1986 Tax Ct. Memo LEXIS 481">*485 public consumption by cooking, frying, baking or broiling. Petitioners are subject to all applicable local health codes and regulations governing the operation of restaurants. These codes and regulations are in addition to those which govern businesses and buildings generally and may set standards or guidelines for preparation and cooking of food, cleanliness, sanitation, employee dress and other related areas. Before a restaurant can open to the general public, a certificate of occupancy must be issued which certifies compliance with all relevant codes and regulations. Continuous compliance is also insured by frequent unannounced inspections by public health officials charged with the enforcement of such codes and regulations.
Emergency lighting consists of lights, batteries, and connections to a building's electrical system. Both wall-mounted and ceiling-mounted models were used by petitioners. The emergency lights were constructed so that their batteries were continuously charged by the building's electrical system and when electrical power was interrupted, the lights would automatically switch to battery power and be turned on. The lights were1986 Tax Ct. Memo LEXIS 481">*486 designed to illuminate large areas of the cafeteria during electrical power failures so customers are able to finish eating their meals during a power outage. In petitioners' cafeterias customers pay for their meal after eating when they exit the cafeterias.
The use of emergency lighting in cafeterias is required by the health and safety codes of each State in which petitioners operate, and the number of emergency lights required is based upon the seating capacity and square footage of the cafeteria. Petitioners' cafeterias may require more emergency lights than a retail store such as a furniture store would require, but each of petitioners' cafeterias had more than the required number of emergency lights. Emergency lights located in the dining rooms were ceiling-mounted models, and wall-mounted models were generally confined to the kitchen. In petitioners' Williamsburg facility, there were 16 emergency lights in the dining room and 3 in the serving line area which would be considered ceiling-mounted models. There were six emergency lights in the kitchen area which would be considered wall-mounted models. The ceiling- or wall-mounted models could be self-contained units that1986 Tax Ct. Memo LEXIS 481">*487 were plugged into a normal electrical outlet but the majority were wired directly to the building's electrical system.
Kitchen panel boards are electrical panel boxes containing circuit breakers that are used to distribute electrical power to the kitchen equipment, but not to lighting, cooling or heating facilities in petitioners' cafeterias. The kitchen panel boards receive electrical power from lines connected to the main panel boxes for each cafeteria (which in turn receives power from outside lines) and distribute power to the kitchen equipment, electric water cooler and wall receptacles through lines connected to the output circuit terminals. The output circuits are graded by size of amperage to conform to the needs of the various pieces of kitchen equipment. The circuits from the kitchen panel boards provide power to kitchen equipment both through direct connections to larger equipment and through wall receptacles. Some circuits to larger equipment have in-line switches between the equipment and the kitchen panel boards to allow interruption of electrical power if necessary. The kitchen panel boards are placed in the cafeterias during the construction1986 Tax Ct. Memo LEXIS 481">*488 of a new cafeteria. The circuits in the panel board may be modified from time to time as electrical requirements dictate.
Each circuit running from the kitchen panel boards supplies electricity to one piece of kitchen equipment. Each circuit leads from a panel board to a specific piece of equipment and back to the panel board. A panel board has room for installation of many circuits. Each circuit requires a circuit breaker to be installed in the panel board and wires lead from the circuit breaker to the equipment. In order to change a circuit or to change minimally the circuit's capacity, a simple change of the circuit breaker on the panel board is necessary. A change from 15 amps to 20 amps is a minimal change that can be accomplished in approximately 5 minutes. In order to increase the power from 15 amps to 50 amps, however, the original conduit must be abandoned, a new conduit must be rerouted and new conductors must be run through it. Panel boards are standard electrical equipment and are not designed and purchased especially for specific machinery or equipment. Panel boards can be used and adapted to supply electricity to almost any type of electrical appliance or equipment. 1986 Tax Ct. Memo LEXIS 481">*489 The kitchen panel boards in issue constitute approximately 50 percent of petitioners' total expenditure for panel boards.
Petitioners provide one or more hand sinks in the kitchen areas to facilitate the washing and cleaning of employees' hands during working hours. The number and location of these sinks are generally determined by local health codes and regulations. Local health codes prohibit employees from washing their hands in the food preparation sink. The sinks in issue are connected to the general plumbing of the building and to the sanitary sewer. The sinks are constructed generally of stainless steel and have large control handles capable of being operated by the employee by using only his elbows or feet. The kitchen hand sinks are part of the original design of a new cafeteria and are placed in use when the cafeteria opens. The kitchen hand sinks are bolted to the walls of the kitchen and are connected to the building's water and sanitary sewer system. If a cafeteria is closed, the kitchen hand sinks are normally removed from the wall by disconnecting them from the water supply and sanitary sewer.
The kitchen1986 Tax Ct. Memo LEXIS 481">*490 water piping is designed to deliver clean water to various equipment located in the kitchen area and the food serving line. The kitchen water piping also delivers water to the kitchen hand sinks and electric water coolers. The kitchen water piping is described as the piping which branches off of the main water lines of the building and brings water to the kitchen area and food serving line. The kitchen water piping is connected to sinks, water coolers nd various items of equipment requiring water for operation. The kitchen water piping connects to equipment used for the following purposes:
(1) Cleaning and rinsing produce.
(2) Cleaning, soaking and rinsing meat, fish and other meat products prior to cooking.
(3) Preparation of food.
(4) Cleaning of employees' hands in kitchen hand sinks.
(5) Cleaning of pots, pans and other utensils.
(6) Ice machines.
(7) Drinking fountains.
(8) Cleaning of kitchen equipment and kitchen area.
The kitchen water piping is installed during the construction phase of a new cafeteria but may be modified with the introduction of new equipment requiring a water source. Once construction is completed, the only visible portion of the piping1986 Tax Ct. Memo LEXIS 481">*491 is that portion which extends to connect with a sink, water cooler or other equipment. The remainder of the piping is buried below the cafeteria's concrete and tile floor or behind the gypsum board walls. The kitchen water piping leads to specific equipment. If petitioners' kitchen equipment were replaced or changed, petitioners could use the same water lines for the new equipment.
Eliason doors are double-action doors installed between the serving line area and the kitchen area. This door is self-closing and lightweight so that employees may open and close the door while carrying food trays in their hands. The doors have a glass panel inset and swing open in area and the serving line area. The doors are purchased by petitioners as a package containing the door, hinges and centering device. Petitioners furnish the door frame separately.
Restroom accessories include paper towel dispensers, electrical hand dryers, cup dispensers, purse shelves, toilet tissue holders, stainless stell soap dispensers and holders, sanitary napkin dispensers and waste receptacles, coat hooks, bars for the handicapped, framed mirrors with shelves1986 Tax Ct. Memo LEXIS 481">*492 and ashtrays. All of these items are not found in all restrooms. These items are either built into or fastened onto the restroom walls or metal partitions at the time the building is constructed, but may be replaced or modified at a later time. These restroom accessories are the type of accessories generally found in any public restroom. The restroom accessories are in both the customer and employee restrooms of the cafeterias. Petitioners have not removed any of the accessories in issue from the restrooms while the restrooms are in operation, unless the removed item is replaced with another similar accessory. The restroom accessories are attached to the restroom's tile wall either by drilling a hole in the wall and using a toggle bolt to bolt the accessory to the wall, or a space is provided for the accessory when the wall is constructed and the accessory is later installed in the space provided.
The decor window treatment consists of a false window built into an interior wall. A light fixture is mounted flush on an interior wall and is covered with a translucent lens. The fixture is then framed in and finished with millwork to resemble a window. 1986 Tax Ct. Memo LEXIS 481">*493 The decor window treatment is designed to simulate a window and not to provide the customer with lighting. The decor window treatment is constructed during the initial construction phase of a new cafeteria. It would be possible to remove decor window treatment and reuse it in a subsequent cafeteria location. Construction of decor window treatment on an interior wall was accomplished by framing in the window out from the wall with only the lighting fixtures recessed into the wall. If the window treatment was constructed on an exterior wall, it was constructed on top of the surface of the wall and was built to resemble a frame protruding out from the wall. When petitioners redecorated a cafeteria every 5 years, they often eliminated or changed the decor window treatment.
The lattice millwork consists of decorative panels made with lattice material approximately 1-3/8 inches X 1/4 inch secured together at right angles that form a diamond shape design. The lattice gridwork was often placed over a wall which is covered with decorative wall coverings in order to simulate an outside garden. The lattice millwork could also be installed between two stationary1986 Tax Ct. Memo LEXIS 481">*494 upright partitions in order to produce a screen between two dining areas. Portions of the lattice millwork were removed, repainted and reused by petitioners in another location when a cafeteria was closed or redecorated.
The vanity cabinets and counters are constructed in restrooms to provide an area for a customer's personal grooming. The vanity cabinets and counters at issue in this case are those provided for petitioners' customers rather than their employees. Petitioners used two types of vanity counters and cabinets in their restrooms. One type was a countertop braced or bracketed to the wall of the restroom and covered with a laminated plastic top. The second type was a full cabinet, placed on the restroom floor and bracketed to the restroom wall. Both types had cutouts for insertion of sinks. The vanity cabinets and counters were constructed by a cabinet maker during the final construction stage of the cafeteria. The cabinet was like any other cabinet found in many public restrooms. The counter was constructed from a two-by-four wood frame, covered by plywood, and was finished with a plastic laminate coat.
1986 Tax Ct. Memo LEXIS 481">*495 The customer line screen is the divider that separates the dining room area from the customers waiting to enter the serving line. Typically, this divider begins near the entrance door and runs along one side of the cafeteria to the serving line in the rear of the cafeteria. Framed openings are usually constructed within the customer line screen to eliminate the tunnel-line appearance of a long hall. Lattice work, spindles, or another open divider are constructed within the framed openings. The entire divider is constructed in the initial construction phase of a new cafeteria. It is usually anchored to the floor and ceiling by screws or nails. The portion of the customer line screen not constituting the framed openings is constructed using wood or metal studs, plates and blocking, and is covered with gypsum wallboard (sheetrock), plywood, paneling or other material. The wallboard or other covering may itself be covered with wallpaper or other decorative covering, such as vinyl, fabric or brick veneer, stain or paint. Portions of the customer line screen were often removed and reused by petitioners at other locations.
The serving line curb1986 Tax Ct. Memo LEXIS 481">*496 is a concrete curb that runs the full length of the serving line, wrapping around the end of the serving line and running partially in the rear of the serving line. The curb is a built-up concrete curb covered with a grouted quarry tile veneer. The curb is constructed during the initial construction phase of the cafeteria and it prevents water and spills from behind the serving line from reaching customers in front of the line and it aids in cleaning the floor. The curb also conceals legs and open space under the serving line steam tables and other equipment. Neither the serving line tables nor the equipment rests on the serving line curb. Such equipment is all freestanding. It is not practical to move a serving line concrete curb because of its construction. A new curb will be built in another cafeteria if petitioners close or sell an existing cafeteria. Serving line concrete curbs are similar, although not identical, to those found in meat markets and grocery stores under counters displaying products for sale.
The kitchen heat recovery unit reduces the cost of heating water for petitioners' cafeterias by collecting heat from the air conditioning1986 Tax Ct. Memo LEXIS 481">*497 system and refrigeration units and using it to preheat cold water to about 110 to 120 degrees before it goes into the cafeteria's hot water heater where it is boosted to 140 or more degrees. Heat is collected, transferred and released by use of a closed-loop, water heat exchange system. This system preheats cold water in a storage tank that has been filled from the municipal water system. The kitchen heat recovery unit is used in conjunction with the cafeteria's plumbing system in providing hot water for kitchen equipment such as the pot sink and dishwasher. The heat recovery system makes efficient use of hot gases which would otherwise be wasted by using such gases to heat water.
The kitchen heat recovery unit is installed with a series of pipes connecting the cold water source, a storage tank and the hot water heater. It also has a series of pipes connecting the air conditioning and heating unit from which it draws the hot gases. Due to the method of installation and the pipes running in the walls, floor and ceiling of the cafeteria, the heat recovery unit is difficult to remove, although it is possible to move the exposed components. The hot water heated by the heat recovery1986 Tax Ct. Memo LEXIS 481">*498 unit generally is used in the public and employee restrooms as well as for cooking and cleaning functions, although a few cafeterias have a separate hot water heater for the public restrooms. The public restrooms which are serviced by the heat recovery unit use approximately 1 percent of the hot water generated by the unit. Equipment such as the dishwasher uses 5-1/2 gallons of 180 degree water a minute for the 8 to 9 hours a day it is in use. The heat recovery unit is adaptable to any business that generates hot gases from air conditioning and refrigeration operations and also consumes large volumes of hot water in operating other equipment.
The cooler, freezer and garbage room floors are constructed with a concrete slab on top of layers of insulation and are more than twice the depth of the floors in the remaining kitchen area. The insulation is necessary to help maintain the cool temperatures and to prevent the kitchen floor from buckling and cracking which may result from the cold temperatures in the freezer causing a buildup of moisture and resulting in a settling of the soil and foundation. The floors are1986 Tax Ct. Memo LEXIS 481">*499 built with the additional insulation when a cafeteria is constructed.
The construction of the cooler, freezer and garbage room floors is as follows: a 4-inch concrete slab is covered with 4 inches of insulation, which is covered by a 3-1/2-inch concrete slab topped with a layer of quarry tile which is set on epoxy and grouted with epoxy. The floors are constructed so that they are only 5/8 inch above the height of the floors in the normal working area of the kitchen.
The refrigerated garbage room is used to store garbage until it can be removed by municipal garbage collectors. Storage in this manner is generally required by local health codes. The garbage room is constructed of concrete blocks with insulation applied to the interior walls and ceiling surface. Insulated panels are then used to cover the walls. The garbage room is part of the building but is accessible only from outside the cafeteria. There is no inside entrance to the garbage room. The garbage room temperature is maintained between 50 to 55 degrees in order to reduce odors and control insects.
The kitchen sanitary wall is a ceramic tile wall extending from approximately1986 Tax Ct. Memo LEXIS 481">*500 6 inches above the floor completely to the ceiling. The kitchen floor tile in issue is a guarry tile floor covering the entire floor area and extending up the walls to meet the ceramic wall tile which is approximately 6 inches up from the floor. The quarry tile has a somewhat rougher surface than the ceramic tile to prevent employees from slipping or falling. The tile floors and walls are constructed during the initial construction phase of the cafeteria. The tile is installed by placing the individual pieces or mats of connected pieces on a wet mortar cement base and a grout mixture is placed in the openings between the tiles. The tile walls and floors are easily cleaned and repetitive cleaning does not harm the appearance of the tile. The tiles are also very wear resistant.
Petitioners are required by local health codes to have the kitchen floors and walls covered with a smooth surface that can be cleaned easily. Petitioners use tile on the walls and floors of their cafeterias in order to facilitate cleaning and maintenance of the kitchen area. After the mortar and grout have dried, removal of the titles is difficult and expensive.
The kitchen1986 Tax Ct. Memo LEXIS 481">*501 air makeup unit is a ventilation system consisting of a roof-mounted fan or blower, ducktwork, and ceiling diffusion grids and it may or may not contain heaters. The purpose of the kitchen air makeup unit is to ventilate the air in the kitchen area of petitioners' cafeterias and to replace the air exhausted from the kitchen by the range exhaust hoods with fresh outside air via air ducts and ceiling outlets. Petitioners are required by local building codes to exhaust approximately 24,000 cubic feet of air per minute from the kitchen due to the extensive cooking in that area. The range exhaust hoods expel large quantities of air containing smoke and odors from the kitchen and the kitchen air makeup unit replaces the exhausted air. Without the air makeup unit, a vacuum would be created in the kitchen area due to the great amount of air that must be exhausted. During the years in issue, prior to installation of air conditioners in petitioners' kitchens, temperatures in the kitchen during the summer could exceed 120 degrees without the air makeup unit bringing fresh air into the kitchen.
During the years in issue, the kitchen area was not air conditioned and air supplied by the kitchen1986 Tax Ct. Memo LEXIS 481">*502 air makeup unit was not air conditioned. However, in certain regions the air may be heated when the outside temperature requires heating. Petitioners installed heaters in the kitchen air makeup units for all cafeterias located north of Ocala, Florida. There were no heaters in the kitchen air makeup units for cafeterias located south of Ocala, Florida. The kitchen air makeup units are not used for air conditioning and heating of the customer dining area. That area is served by a different air conditioning/heating system.
The kitchen air makeup units supply 90 percent of the replacement air for air exhausted from the kitchen. The remaining 10 percent of air is replaced from the dining room of the cafeterias to prevent kitchen odors from entering the dining room.
The air makeup unit is located either on the roofs of the cafeterias or between the finished ceilings and the roofs. The ductwork is located between the ceilings and the roofs. The only part of the system visible from the kitchen area is the grating located in the kitchen ceilings.
The kitchen drainage in issue represents several components used in a system that drains water and liquid waste1986 Tax Ct. Memo LEXIS 481">*503 from the kitchen sinks and floors through piping to a grease trap pretreatment unit and then onto the connection with the local sanitary system. Included in the kitchen drainage system are floor drain covers, open air drains, recessed openings in the slab floor, P traps, Y connections, T connections, piping and pipe connections, and grease traps. The components are constructed together to form a drainage system during the construction phase of a new cafeteria. Only the floor drain covers and the recessed openings are visible once the cafeteria is placed in service. The remainder of the system is concealed in the slab floors, behind finished walls or is buried in the ground outside the cafeterias.
There are two types of drains used in petitioners' cafeterias. The first type is the hub, or open air drain. This drain allows an air gap to the drainage system and the equipment being drained. This type of drain is required by local health codes for equipment in which food is prepared. The open air drain prevents waste from being flushed back into the equipment through the drainage system. The second type of drain is the floor drain, which consists of grates in the floor connected1986 Tax Ct. Memo LEXIS 481">*504 to the drainage system. The floor drains are used to drain wash water from the floor after the area has been cleaned. The floor drains can also be located immediately beneath a piece of equipment and serve the same purpose as a hub drain.
In the hub drain, a pipe from the equipment being drained leads to a larger opening, or hub, into which the waste drains. There is an air gap between the receiving hub and the discharging pipe from the equipment. There is no special connector used in this drain.
The grease trap pretreatment units which collect the waste from the kitchen drains are located outside of the cafeterias. A grease trap is an enclosed chamber installed in the ground near the cafeteria. It is designed to receive waste water from the kitchen drainage system and pretreat the influent by removing grease and food particles prior to discharging the waste water into the municipality's sanitary sewer system. The grease trap must be of sufficient size to permit an adequate detention period to allow suspended grease to float to the top of the tank and food particles to settle to the bottom.
If petitioners closed or sold a cafeteria, the drainage system would be left in the1986 Tax Ct. Memo LEXIS 481">*505 floor rather than moved to a new location. It would not be feasible to tear up the floors in order to get to the drains. If petitioners replace a piece of equipment for which the existing drain is not suitable, that drain would be blocked off and new drainage would be installed.
The electric water coolers, located in the kitchen area of the cafeterias, provide cool drinking water solely to petitioners' employees during the day. The water coolers are not used by petitioners' cafeteria customers. The water coolers are connected to the fresh water supply system and kitchen drainage system by the use of standard plumbing connections. Water coolers, which are electrical-powered refrigeration units, chill the water prior to its use. Water coolers can be either wall-mounted or freestanding. In either case, the plumbing connections will be direct connections with the building's plumbing system. The wallmounted water coolers are attached to and are supported by the wall framing by means of reinforced bracing or wall brackets concealed behind the finished wall surface.
The electric water coolers are provided to petitioners' employees in order to allow1986 Tax Ct. Memo LEXIS 481">*506 them to drink cool water without using water glasses which may break. In some geographic areas, petitioners are required by local health codes to provide electric water coolers for their employees. When petitioners move a cafeteria, the water coolers are moved to the new location.
Chandeliers are ceiling-hung light fixtures with a frame providing multiple lighting elements. A chandelier will generally be attached to a support bracket mounted to a structural portion of the ceiling. A single chain may be used to suspend the chandelier above the dining area. The chandelier will generally use bulbs with wattage ratings ranging from 15 watts to 25 watts, but the bulbs may range up to 40 watts. The chandelier wiring consists of direct wire connections to conjunction boxes installed in the ceilings. The wiring is then connected to the building's electrical system. When one of petitioners' cafeterias is remodeled every 5 years, the chandeliers are often changed or can be replaced by ceiling fans.
Decor wall lights are wall-mounted lights, mounted by bolting the fixtures to the finished walls. The wiring connections1986 Tax Ct. Memo LEXIS 481">*507 are concealed behind the base plates of the wall fixtures and behind the finished walls. Typically, the wall lights will be designed and coordinated to match the design of the chandleiers. The chandeliers and decor wall lights in issue provide from 5 percent to 40 percent of the available lighting in both the dining and kitchen areas of petitioners' cafeterias. The chandelier lights and wall lights are controlled by circuit breakers in the lighting panel box.
Dimmer switches are installed on the circuit wiring to the chandeliers and wall lights. The dimmer switches are variable rheostats that permit the cafeteria manager to vary the lighting intensity within the dining area as desired. The switches are mounted to the walls by screws and are placed directly over the outlet boxes for direct connection to the building's electrical system.
The hot water heater in issue is a 300 or 400 gallon capacity tank with nickel, steel or glass lining that is insulated and receives either cold water or water that has been warmed and produces 140 or higher degree water. The hot water heater provides hot water for the kitchen appliances and equipment and in most1986 Tax Ct. Memo LEXIS 481">*508 cafeterias for both the employee and customer restrooms. However, less than 1 percent of the hot water used in petitioners' cafeterias is used in the public restrooms. The size of the hot water heater is based upon the amount of water that is being used in the sinks, the kitchen equipment and the dishwasher, per hour. The connection from the hot water heaters in issue to the various appaliances and restrooms is through pipes located in the walls, ceiling or floor. A subsequent user of the building such as a retail establishment that did not use substantial amounts of hot water would have no use for the oversized water heaters in issue.
In petitioners' cafeterias, the portion of the electrical distribution system that brings in electricity from the outside source and feeds the electricity to the primary distribution point is referred to as the primary electric system. The primary electric system includes the wires and conduits from the outside power source, any transformer needed at this stage and the main distribution panel including the primary power switchgear. 5
1986 Tax Ct. Memo LEXIS 481">*509 The secondary electric system in petitioners' restaurants distributes electricity from the main distribution panel to the kitchen equipment panels and the lighting panels. It includes the wiring and conduit (lighting panel feeder wires and kitchen panel feeder wires) from the main distribution panel to the subsidiary panels, and the subsidiary panels themselves, including the kitchen panel boards and the lighting panel boards. The consumptive devices in petitioners' restaurants are the ultimate users of electrical power. They include the wiring and conduit leading to those devices. The consumptive devices include lighting fixtures for the restaurant; kitchen equipment branch wiring (for which investment tax credit has already been allowed); kitchen appliance wiring (investment tax credit allowed); building service branch wiring for heating, ventilation and air conditioning equipment, receptacles, restrooms, cash registers, etc.; emergency lighting; yard lighting; and miscellaneous other electrical wiring and components.
The breakdown of costs attributable to the various components of the electrical distribution system are as follows:
Name | FY 1977 | FY 1978 | Total |
Primary Electric | |||
Incoming Power Wiring | $ 16,331 | $32,876 | $49,207 |
Primary Power Switchgear | 73,310 | 147,577 | 220,887 |
Secondary Electric | |||
Lighting Panel Feeder Wires | 9,259 | 18,639 | 27,898 |
Kitchen Panel Feeder Wires | 10,923 | 21,989 | 32,912 |
Lighting Panel Boards | 22,142 | 44,574 | 66,716 |
Kitchen Panel Boards * | |||
K/K1/K2/K3 | 23,722 | 86,008 | 109,730 |
Consumptive Devices | |||
Building Service Branch | |||
Wiring (Includes Conduit | |||
Cost 75% of Total) | 84,675 | 170,455 | 255,130 |
Kitchen Equipment Branch | |||
Wiring | 80,042 | 91,331 | 171,373 |
Lighting Fixtures | 154,425 | 310,867 | 465,292 |
Miscellaneous Installations | |||
(1) Emergency Lighting | 36,351 | 57,099 | 93,450 |
(2) Chandelier Installation | |||
and Wall Decor Lights | 5,397 | 4,026 | 9,423 |
(3) Miscellaneous Other | |||
Electrical Installation | 98,846 | 148,060 | 246,906 |
Yard Lighting | 57,798 | 116,350 | 174,148 |
Total Electrical | |||
Distribution System Costs | $673,221 | $1,249,851 | $1,923,072 |
A study was conducted by Pennsylvania State University1986 Tax Ct. Memo LEXIS 481">*511 to measure the electrical consumption of seven typical food service operations including petitioners' Williamsburg, Virginia cafeteria. The study metered five basic areas of electrical consumption common to each of petitioners' cafeterias:
1. Food preparation
2. Sanitation
3. Refrigeration
4. Lighting
5. Heating, ventilation and air conditioning
The percentages of all kilowatt hours of the electricity used by petitioners in their Williamsburg cafeterias attributable to the electrical consumption necessary to power machinary and equipment was 69.2 percent for the period studied.
The "load" on an electrical circuit is expressed in terms of voltage or kilovolt-amperes (kVA). A kilovoltampere is the voltage (in thousands) multiplied by the amperes of the circuit. The load of an electrical circuit is commonly considered to be the amount of electricity flowing through the circuit and is synonymous with power, or power demand. The loads on the electrical circuits in petitioners' cafeterias at issue and the division of the loads between circuits used to power machinery and equipment and circuits used to power the operation and maintenance function of the restaurant building1986 Tax Ct. Memo LEXIS 481">*512 measured as the percentage of the kilovolt-amperes load going into each of petitioners' restaurants is as follows: 6
With Kitchen Air | With Kitchen Air | ||
Makeup Unit | Makeup Unit | ||
Not Qualifying | or | Qualifying | |
Restaurant | For Credit | For Credit | |
FISCAL YEAR 1977 | |||
Titusville, FL | 62.5 | 64.4 | |
Altamonte Springs, FL | 53.6 | 55.1 | |
Pinellas Square, FL | 53.6 | 55.1 | |
Lexington Mall, KY | 41.6 | 42.9 | |
Raceland Mall, KY | 53.9 | 55.5 | |
Tampa Bay Center, FL | 53.6 | 55.1 | |
Eastlake Square, Tampa, FL | 48.5 | 49.9 | |
Winterhaven, FL | 53.6 | 55.1 | |
Panama City, FL | 55.8 | 57.4 | |
Biloxi, MS | 53.6 | 55.1 | |
Albany, GA | 41.4 | 42.7 | |
FISCAL YEAR 1978 | |||
Eastdale Mall, AL | 65.8 | 67.7 | |
Carbondale, IL | 53.7 | 55.3 | |
Whitehaven, TN | 51.1 | 52.6 | |
Coral Springs, FL | 48.5 | 49.9 | |
Sarasota, FL | 59.0 | 60.8 | |
Florence, KY | 50.1 | 51.6 | |
Naples, FL | 53.0 | 54.5 | |
Oaks Mall, FL | 53.9 | 55.5 | |
Vero Beach, FL | 63.4 | 65.2 | |
Owensboro, KY | 51.7 | 53.3 | |
Regency Square, FL | 56.3 | 58.0 | |
Winter Park, FL | 64.7 | 66.6 | |
Tupelo, MS | 48.5 | 49.9 | |
Metro Center, Jackson, MS | 61.0 | 62.9 | |
Hammond, LA | 65.2 | 67.1 | |
Columbia Mall, SC | 56.6 | 58.3 | |
Woodhill Center, SC | 51.5 | 53.0 | |
Williamsburg, VA | 49.2 | 50.7 |
The electrical distribution system consists of standard electrical equipment that is purchased off the shelf from electrical equipment suppliers and is used in a wide variety of buildings. The electrical distribution system can be used and adapted to supply electricity to almost any type of electrical appliance or equipment. Since the electrical distribution system consists of components manufactured for general electrical use, a subsequent tenant in a similar food service business might be able to adapt the electrical distribution system in petitioners' cafeterias for his own use.
The electrical system leading to petitioners' cafeterias was more than adequate for the normal and customary stores or businesses that would be possible tenants for space in a building, shopping center or mall. Petitioners' cafeterias typically have 30 and 40 watts a square foot in electrical capacity whereas office space or shopping centers use only 15 watts a square foot.
During the years at issue in this case, petitioners constructed several cafeterias1986 Tax Ct. Memo LEXIS 481">*514 and equipped them with items for which they claimed investment tax credits on their tax returns.
In the notices of deficiency issued to petitioners for tax years ending May 28, 1977, and June 3, 1978, respondent disallowed petitioners' claim of investment tax credit on numerous items including the 19 items which remain in issue in this case with the explanation that the investment credit was claimed on property not constituting qualified section 38 property as defined in
OPINION
1986 Tax Ct. Memo LEXIS 481">*515 Section 38 allows a credit against tax for investments in certain types of property, described as "section 38 property." In relevant part,
(a) Section 38 Property.--
(1) In general.--Except as provided in this subsection, the term "section 38 property" means--
(A) tangible personal property (other than an air conditioning or heating unit), or
(B) other tangible property (not including a building and its structural components) but only if such property--
(i) is used as an integral part of manufacturing, production, or extraction or of furnishing transportation, communications, electrical energy, gas, water, or sewage disposal services, * * *
Tangible personal property is defined in
For purposes of this section, the term "tangible personal property" means any tangible property except land and improvements thereto, such as buildings or other inherently permanent structures (including items which1986 Tax Ct. Memo LEXIS 481">*516 are structural components of such buildings or structures). * * * Tangible personal property includes all property (other than structural components) which is contained in or attached to a building. * * *
A "structural component" of a building is ineligible for an investment tax credit and that term is defined in
(2) The term "structural components" includes such parts of a building as
This Court has held that
Petitioners take the primary position that all the items in issue are tangible personal property within the meaning of
Respondent contends that the various items in issue are not "tangible personal property" as defined in the regulations and that since petitioners were not engaged in manufacturing or production of food products but rather in the retail sale of such products, the provisions with respect to "other tangible property" are not applicable to them.
We will first address petitioners' contentions that they are in the business of manufacturing or production within the meaning of
In our view, petitioners' activity of operating cafeterias was a retail activity rather than a "manufacturing" or "production" activity within the meaning of
"manufacturing", "production", and "extraction" include the construction, reconstruction, or making of property out of scrap, salvage, or junk material, as well as from new or raw material, by processing, manipulating, refining, or changing the form of an article, or by combining or assembling two or more articles, * * *. Thus, section 38 property would include * * * the processing of meat, fish, or other foodstuffs; * * *
As used in
Petitioners operated retail cafeterias and the preparation of food incidental1986 Tax Ct. Memo LEXIS 481">*520 to the retail sale of such food to the general public for consumption is not considered a manufacturing or producing activity. In
Activities involving the sale of merchandise and food to the general public for personal or household consumption and the rendering of services incidental to the sale of such goods are considered retail activities rather than manufacturing or producing activities. See
There is no distinction in petitioners' food preparation in the1986 Tax Ct. Memo LEXIS 481">*521 instant case and the taxpayer's meat preparation in the
Therefore, in this case our determination of whether petitioners are entitled to the claimed investment tax credits depends on whether the items are "tangible personal property" within the meaning of
As we pointed out in
(1) Is the property capable of being moved, 1986 Tax Ct. Memo LEXIS 481">*522 and has it in fact been moved? * * *
(2) Is the property designed or constructed to remain permanently in place? * * *
(3) Are there circumstances which tend to show the expected or intended length of affixation, i.e., are there circumstances which show that the property may or will have to be moved? * * *
(4) How substantial a job is removal of the property and how time-consuming is it? Is it "readily removable"? * * *
(5) How much damage will the property sustain upon its removal? * * *
(6) What is the manner of affixation of the property to the land? * * *
See
Under the criteria set forth above and bearing in mind that the term "tangible personal property" is not to be narrowly defined for purposes of
Petitioners state that the primary purpose for the installation1986 Tax Ct. Memo LEXIS 481">*523 of the emergency lighting is to provide ample lighting for customers to finish their meals in the event of a power failure and to provide assurances that petitioners will be able to collect the amount owed by their customers. In petitioners' cafeterias, customers pay for their meals only after they have finished eating. Petitioners argue that the emergency lighting in issue is far in excess of that necessary for safety reasons in case of a power failure and serves only an incidental function of providing light for such safety requirements. Petitioners consider the emergency lighting as tangible personal property within the meaning of
Respondent argues that "lighting fixtures" are specifically mentioned as structural components in
In our view, petitioners' emergency lighting qualifies for the investment tax credit as tangible personal property because1986 Tax Ct. Memo LEXIS 481">*524 it meets many of the criteria for such property outlined in the
In addition, the committee wishes to clarify present law by stating that tangible personal property already eligible for the investment tax credit includes
In our view the emergency lighting qualifies as "special lighting." Consequently, emergency lighting is not a structural component of the building but instead is tangible personal property and as such qualifies for the investment credit.
Petitioners contend that since the kitchen panel boards are necessary to and are used directly with specific items of machinery or equipment they are not structural components but constitute tangible personal property within the meaning of
Respondent contends that the kitchen panel boards are part of the electrical wiring system of petitioners' cafeterias and are therefore specifically designated as structural1986 Tax Ct. Memo LEXIS 481">*526 components by
In our view the kitchen panel boards, which are merely holding devices for the circuit breakers that connect the electrical supply wires leading to the kitchen appliances, are necessary to and are used directly with specific items of kitchen machinery or equipment in petitioners' cafeterias. The kitchen panel boards in issue are thus distinguishable from the general equipment panel boards used to provide electricity to the remainder of the cafeteria.
We conclude that the kitchen panel boards are eligible for the investment tax credit as tangible personal property because they constitute assets accessory to petitioners' business.
The kitchen hand sinks are necessary solely and exclusively because petitioners are engaged in food processing. Petitioners emphasize that the sinks are required by local codes to be located in the kitchen work areas in order to promote cleanliness by encouraging employees to wash their hands and are readily removable without any material damage to the premises. For these reasons, petitioners contend that the sinks constitute tangible personal property within the meaning of
Respondent contends that the kitchen hand sinks are plumbing1986 Tax Ct. Memo LEXIS 481">*528 fixtures that relate to the operation or maintenance of the building within the meaning of
The kitchen hand sinks do not function as specialized items of machinery or equipment even though the sinks are generally removed when a cafeteria is closed. They are bolted to the wall and connected to the plumbing system in a way to make removal difficult. These sinks are a part of the plumbing system. An application of the
Petitioners claim that the kitchen water piping constitutes "other tangible property" because it is essential for the operation of specific pieces of petitioners' kitchen machinery and equipment and the preparation of foodstuffs. Petitioners emphasize that the removal of the kitchen water piping would not affect the cafeteria's main water piping and sanitary drainage and thus does not relate to the operation or maintenance of the building. In petitioners' view, the kitchen water piping is used as an integral part of petitioners' processing activities and is essential to the completeness of those activities.
Respondent contends that the kitchen water piping is part of the building's plumbing system and is thus a structural component within the meaning of
In
1986 Tax Ct. Memo LEXIS 481">*532
According to petitioners, the Eliason doors which are special lightweight, double action doors installed to prevent accidents in the heavily trafficked area between the serving lines and the kitchen, do not serve a function merely as a front or rear door but are specially designed with a window to enable employees to move between the kitchen and the serving line without using their hands. Petitioners argue that the Eliason doors serve their specialized needs and are thus tangible personal property within the meaning of
Respondent argues that "doors" are specifically mentioned as "structural components" of a building in
The Eliason doors constitute a structural component only if they are a permanent part of the cafeteria building, 1986 Tax Ct. Memo LEXIS 481">*534 so that their removal would affect the essential structure of the building.
Tangible personal property is not intended to be defined narrowly here, nor to necessarily follow the rules of State law. It is intended that assets accessory to a business such as grocery store counters, printing presses, individual air-conditioning units, etc., even though fixtures under local law, are to qualify for the credit. Similarly, assets of a mechanical nature, even though located outside a building, such as gasoline pumps, are to qualify for the credit. * * * [S. Rept. 1881, 87th Cong., 2d Sess. (1962),
In our view the Eliason doors did not function as an integral part of the cafeterias and were not designed to be used as a permanent feature of the cafeterias. Removal of the doors would not detract significantly from the usefulness of the cafeterias because they have no more than an incidental relationship to the operation or maintenance of the building. The doors were necessary to assist petitioners in the operation of their1986 Tax Ct. Memo LEXIS 481">*535 cafeterias by providing their employees with easy and safe passage in and out of the kitchen area of the cafeterias. The record reflects that the doors were temporary attachments that could be removed easily and quickly. We conclude that the Eliason doors are not structural components of the cafeterias and thus qualify for the investment tax credit.
Petitioners contend that the restroom accessories constitute tangible personal property within the meaning of
Respondent contends that the restroom accessories in issue are similar to those found in any public restroom and that these items relate to the operation or maintenance of the building rather than to petitioners' operation of a cafeteria. Respondent argues that all buildings open to the public must have restrooms and these restrooms usually include accessories1986 Tax Ct. Memo LEXIS 481">*536 like those in issue. These accessories, according to respondent, were not involved in an activity specifically related to the operation of a cafeteria. Respondent cites a District Court opinion from the Eastern District of North Carolina,
In our view, the restroom facilities do not qualify for the credit because they are not an integral part of petitioners' business of operating a cafeteria. The accessories serve no function particularly unique to a cafeteria. The restroom accessories relate to the overall operation or maintenance of the building and as such are structural components. 1986 Tax Ct. Memo LEXIS 481">*537
Petitioners take the view that the decor window treatment serves purely a decorative function and is changed every 5 years in conjunction with other changes in petitioners' decorative plan. The window treatment, according to petitioners, does not serve a function relating to the operation or maintenance of the building because the simulated windows are impossible to see through and function merely as ornamentation. Removal of the decor wall treatment would not detract from the cafeterias's function, according to petitioners, and thus the decor window treatment constitutes tangible personal property.
Respondent argues that the decor window treatment was used as part of the permanent wall coverings and therefore is strictly defined as structural components in
We conclude that the decor wall treatment1986 Tax Ct. Memo LEXIS 481">*538 qualifies for the investment tax credit because it serves no more than an incidental relationship to the operation or maintenance of the building. The Senate stated in Report No. 95-1263:
In addition, the committee wishes to clarify present law by stating that tangible personal property already eligible for the investment tax credit includes * * * false balconies and
The decor window treatment served merely a decorative function in the cafeterias. It is changed approximately every 5 years in conjunction with the redecoration of the entire cafeteria. In our view, the window treatments do not contribute to the operation or maintenance of the building and thus constitute personal property eligible for the credit. Removal of the decor wall treatment1986 Tax Ct. Memo LEXIS 481">*539 would not damage the underlying wall. Any marks or holes left in the wall would be minimal.
Petitioners state that the lattice millwork is also a decorative item which is replaced every 5 years and does not relate to the operation or maintenance of the building. Petitioners contend that the lattice millwork constitutes readily removable tangible personal property.
Respondent argues that the lattice millwork is part of the permanent covering of the walls and thus constitutes structural components within the meaning of
As stated in Senate Report No. 95-1263, the lattice millwork has "no more than an incidental relationship to the operation or maintenance of a building." "Removable partitions, * * * which are attached to walls or suspended from the ceiling, are considered tangible personal property and not structural components." S. Rept. 95-1263 (1978), 1978-3 C.B. (Vol. 1) 321, 415. We conclude that the lattice millwork qualifies as personal property eligible for the investment tax credit. The lattice millwork is merely decorative ornamentation serving no more than an incidental1986 Tax Ct. Memo LEXIS 481">*540 relationship to the operation or maintenance of the building. Although the lattice millwork may be used to physically separate the serving line from the dining portions of the cafeteria, it does not serve as a structural support for the ceiling of the cafeteria. The lattice millwork could easily be removed without permanently damaging the underlying ceiling or walls and its removal would not entail great expense. The lattice millwork is tangible personal property qualifying for the investment tax credit.
Petitioners state that they are required by local occupancy codes to install more restroom facilities such as vanity cabinets and counters than would be required in a building of the same size used for general purposes due to their business of serving large numbers of people at one time. Petitioners conclude that the vanity cabinets and counters are thus accessory to their business of operating a cafeteria.
Respondent contends that the counters and cabinets are attached permanently to the building because they are bolted to the wall. Respondent also argues that the vanity cabinets and counters could be used by any subsequent tenant occupying1986 Tax Ct. Memo LEXIS 481">*541 the cafeteria premises and do not relate specifically to petitioners' particular business. Respondent concludes that the vanity cabinets and counters were a necessary part of petitioners' public restrooms and are thus necessary in the operation or maintenance of the building within the meaning of
In our view the vanity cabinets and counters constitute structural components of the buildings and do not serve a function unique to petitioners' business. They are not accessory to petitioners' business of operating a cafeteria. The regulations specifically provide that "plumbing and plumbing fixtures, such as sinks and bathtubs" constitute structural components ineligible for the credit. The record reflects that the counters and cabinets were permanently attached to the walls of the restrooms and that removing them would damage the underlying walls.
Petitioners state that the customer line screen is designed to direct customers to the serving line. Petitioners argue that the line screen is not used as a wall separating1986 Tax Ct. Memo LEXIS 481">*542 rooms and supporting the ceiling but is a decorative partition required by petitioners' particular business needs. The line screen, according to petitioners, is integrally related to the line cafeteria concept and removal of the line screen would not in any way detract from the usefulness of the building but would impair petitioners' efficient control over the travel of customers in the cafeteria.
Respondent takes the view that the customer line screen is a structural component due to the inclusion of "walls" and "partitions" in the definition of structural components in
1986 Tax Ct. Memo LEXIS 481">*544 The Senate Finance Committee, in its Report No. 95-1263 (1978), 1978-3 C.B. (Vol. 1) 321, 415, issued in connection with the enactment of the Revenue Rule Act of 1978, Pub. L. 95-600, 92 Stat. 2767, stated as follows:
In addition, the committee wishes to clarify present law by stating that tangible personal property already eligible for the investment tax credit includes * * * movable and removable partitions * * *
The customer line screen at issue in the instant case was a decorative partition separating the dining room from the cafeteria serving line and, like the movable partitions involved in
We conclude that the customer line screens constitute personal property eligible for the investment tax credit.
Petitioners state that the purpose of designing and installing the serving line concrete curb was to prevent water from seeping into the customer side of the serving line and as such it is essentially part of the serving line equipment. Petitioners argue that the concrete curb aids essentially in cleaning1986 Tax Ct. Memo LEXIS 481">*545 which is not a function relating to the operation or maintenance of the building.
Respondent contends that the serving line concrete curb is permanently attached to the building and is constructed of brick or concrete blocks that are cemented or mortared to the floor and are covered with quarry tile. Moving the curb would be impractical according to respondent. Respondent notes that if petitioners closed a cafeteria, they left the serving line concrete curb and constructed another one at the new site. 10
Applying the
Petitioners argue that the kitchen heat recovery unit is section 38 property because it constitutes "machinery the sole justification for the installation of which is the fact that such machinery is required to meet temperature * * * requirements which are essential for the operation of other machinery or the processing of * * * foodstuffs."
Respondent contends that the heat recovery system is part of the building's plumbing system and is thus considered a structural component under
Without consideration of the "sole justification" test, the heat recovery system, consisting of circulation pipes and tubing, might be considered to constitute part of the plumbing system of petitioners' cafeterias and thus constitute a structural component. However, in
Petitioners contend that the cooler, freezer and garbage room floors which have more insulation than floors in the remaining portions of the cafeteria, were designed and installed to function as items of machinery and thus constitute tangible personal property.
Respondent states that the cooler, freezer and garbage1986 Tax Ct. Memo LEXIS 481">*549 room floors were the same as the floors in the remaining portions of the kitchen area, except that they were elevated approximately 5/8 inch above the remaining floors and had 4 inches of insulation and 4 inches of concrete beneath them which did not exist under other floors in the cafeteria. 11 Respondent also argues that floors are specifically defined as being structural components in
Structural components are defined in the regulations to1986 Tax Ct. Memo LEXIS 481">*550 include "floors."
Although the floors in issue may differ somewhat from the floors in the remaining portions of the cafeteria due to the fact that they are built on extra insulation, they nevertheless are floors. We consider them to be structural components due to the permanent nature in which they are installed. It would be difficult to remove them and removal would damage the underlying foundation.
Senate Report No. 95-1263 states as follows with respect to floors:
Similarly, floor coverings which are not an integral part of the floor itself such as floor tile generally installed in a manner to be readily removed (that is it is not cemented, mudded, or1986 Tax Ct. Memo LEXIS 481">*551 otherwise permanently affixed to the building floor but, instead, has adhesives applied which are designed to ease its removal) * * * are considered tangible personal property and not structural components. * * * [S. Rept. 95-1263 (1978), 1978-3 C.B. (Vol. 1) 321, 415.]
The cooler, freezer and garbage room floors here in issue could not be removed without substantial damage to the building and therefore constitute structural components of the cafeterias.
We next consider whether the garbage room constitutes section 38 property. Petitioners maintain that the garbage room constitutes "other tangible property" used as an integral part of manufacturing or production under
Respondent argues that the garbage room is part of the building itself and therefore not tangible personal property. Respondent emphasizes that the garbage room has walls, a floor, a ceiling, provides shelter, as well as a working space, and is thus part of the cafeteria building within the meaning of
Petitioners claim that the kitchen wall and floor tiles are eligible for the credit because their cafeterias are required by local codes to have readily cleanable surfaces in order to maintain sterile and sanitary conditions and inhibit bacterial1986 Tax Ct. Memo LEXIS 481">*555 growth. Petitioners argue that the sanitary wall and floor tiles serve a business function particularly suited to their food processing operation and that the sanitary wall and floor tiles do not relate to the operation or maintenance of the building. Petitioners further argue that the removal of the floor and wall tiling would in no way alter the operation of a building because many buildings function with exposed concrete block, brick or painted surfaces.
Respondent contends that "tiling" is specifically defined as a structural component in
1986 Tax Ct. Memo LEXIS 481">*556 We agree with respondent that the kitchen wall and floor tiles constitute structural components of the cafeterias due to their permanent attachment by means of mortar or grout. In addition, the tiles are specifically mentioned as structural components in
Petitioners take the view that the kitchen air makeup unit aids them in satisfying ventilation requirements which are essential to the processing of foodstuffs in petitioners' cafeterias. Petitioners argue that the kitchen air makeup unit is analogous to the HVAC units in
Respondent contends that the kitchen air makeup unit substitutes for a ventilation system in petitioners' cafeterias and therefore is a structural component within the meaning of
The purpose of the kitchen air makeup unit is to replace the 24,000 cubic feet per minute of air that is exhausted from the kitchen with filtered outside air via ducts in ceiling outlets. In our view the kitchen air makeup unit is analogous to the HVAC units that the taxpayer in
Here, as in the
Respondent's contention that petitioners' air makeup unit substituted for a ventilation system in the cafeterias is not supported by the evidence.
Petitioners contend that the kitchen drainage constitutes tangible personal property because it was used as an integral part of their cafeteria operation and thus does not relate to the operation or maintenance of their cafeteria buildings.
Respondent contends that the kitchen drainage system was a part of the building's plumbing system1986 Tax Ct. Memo LEXIS 481">*561 within the ordinary meaning of that word and that "plumbing and plumbing fixtures" are specifically defined as structural components in
We find the sewage disposal system in
1986 Tax Ct. Memo LEXIS 481">*563 In our view petitioners' kitchen drainage system from the point the connecting devices couple to the drainage system is analogous to the electric wiring in
We focus on petitioners' use of the drains in the kitchen and conclude that they do not relate to the general drainage of waste from the building but rather, drain wastes resulting from petitioners' food preparation activities. Despite the apparent character of the kitchen drainage as a permanent plumbing fixture, we conclude that it actually services petitioners' equipment and machinery 16 and is thus eligible for the credit as section 38 property.
Petitioners contend that they are entitled to the credit on the electric water coolers because the primary purpose of the coolers was to prevent employees from using glasses in the kitchen area where the risk of broken glass falling into the food would create a significant hazard. Petitioners argue that the water coolers do not serve a function relating to the operation or maintenance of the building.
Respondent argues that the1986 Tax Ct. Memo LEXIS 481">*565 electric water coolers provided water for petitioners' employees and were thus part of the building's overall plumbing system. Respondent argues that the water coolers related to the operation or maintenance of the building within the meaning of
We agree with respondent and conclude that water coolers constitute structural components because they are "plumbing and plumbing fixtures" which are structural components as defined in
Petitioners contend that the chandeliers and decor wall lights were installed only for decorative purposes and they did not exist to provide general room illumination as there was ample1986 Tax Ct. Memo LEXIS 481">*566 lighting throughout the cafeteria for such purpose. Petitioners conclude that the decorative lighting was not intended to and did not relate to the operation or maintenance of the building.
Respondent contends that the "lighting fixtures" in a building are specifically defined in
1986 Tax Ct. Memo LEXIS 481">*568 The chandeliers and decor wall lights used in petitioners' cafeterias were purely decorative fixtures which were designed specifically to compliment petitioners' decorative motif in specific cafeterias. The chandeliers and decor wall lights in issue used low wattage of 15 watt bulbs as compared to 150 or 75 watt bulbs which were used for the recessed lighting fixtures which are not at issue in this case. As stated in Senate Report No. 95-1263, "tangible personal property already eligible for the investment credit includes special lighting (including lighting to illuminate the exterior of a building or store, but not lighting to illuminate parking areas) * * *." 1978-3 C.B. (Vol. 1) at 415.
We conclude that the chandeliers, decor wall lights, and dimmers constitute section 38 property because they constitute "special lighting," are assets accessory to petitioners' business, are readily movable and do not relate to the operation or maintenance of the building. The chandeliers and decor wall lights in issue were not the major source of light in the cafeteria and merely incorporated petitioners' decorative motif and complimented the interior design of its cafeterias.
1986 Tax Ct. Memo LEXIS 481">*569 Petitioners are not entitled to a credit for installation of the chandeliers, decor wall lights or dimmers because installation is not "tangible personal property" or "other tangible property."
Petitioners contend that the hot water heater is "machinery the sole justification for the installation of which is the fact that such machinery is required to meet temperature * * * requirements which are essential for the operation of other machinery or the processing of * * * foodstuffs."
Respondent contends that the hot water heater is an integral part of the building's plumbing system because it provides hot water for the kitchen operations as well as for the public and employee restrooms. Thus respondent concludes that the hot water heater functions in the operation or maintenance of the building and thus is a structural component1986 Tax Ct. Memo LEXIS 481">*570 within the meaning of
In our view petitioners' sole justification for the installation of a kitchen hot water heater with a 300 or 400-gallon capacity was to meet the extensive hot water requirement for the operation of their kitchen machinery or equipment. Thus, we find that pursuant to
Petitioners filed claims for refunds claiming an investment tax credit for the percentage of the cost of the cafeterias' primary electrical distribution system they consider allocable to the service of cafeteria-related machinery and equipment. Petitioners determined the eligible percentage by measuring the electrical consumption in watts or kilowatts at the Williamsburg, Virginia, cafeteria. They determined that the percentage of kilowatt hours attributable to the electrical consumption necessary to power eligible machinery and equipment was 69.2 percent. They applied this percentage to the total electrical costs of $1,923,072 to arrive at a claim for investment tax credit of $1,330,766. From this figure, they subtracted the amount previously claimed of $630,882 to arrive at an additional amount claimed of $699,884. 19
Petitioners support their allocation of the electrical distribution system between1986 Tax Ct. Memo LEXIS 481">*572 the structural and processing-related functions on the basis of consumption of electrical power by citing
a descriptive phrase intended to present the basic test used for identifying structural components. The preceding elements are examples of items which meet that test as a general rule. Items which occur in an unusual circumstance and do not1986 Tax Ct. Memo LEXIS 481">*573 relate to the operation or maintenance of a building should not be structural components despite being listed in
We also quoted the Technical Explanations of the Revenue Act of 1962 which explained the language which was incorporated in the regulation as follows:
The term "structural components" of a building includes such parts of the building as central air-conditioning and heating systems, plumbing, and electric writing and lighting fixtures, relating to the operation [or] maintenance of the building. [H. Rept. 1447, 87th Cong., 2d Sess. (1962),
In accordance, we concluded that property fails to qualify for the credit if it relates to the overall operation or maintenance of a building rather than being used to aid in the employment of a particular function or particular piece of property. See
We focused on the ultimate uses of power at the taxpayer's facility in
To the extent that the primary electric carried electrical loads to be used for
To the extent that the primary electric improvements relate to the
Petitioners state that the investment tax credit was claimed only on the portion of the primary electrical distribution1986 Tax Ct. Memo LEXIS 481">*575 system which is directly applicable to the operation of the machinery and equipment. Petitioners also add that subsequent tenants would have very little use for an electrical distribution system with 5 to 10 times the capacity that would be required for the operation or maintenance of a general purpose building.
Respondent disallowed petitioners' claims for refund for the entire primary electrical distribution system of the cafeterias with the explanation that the system was a structural component of the buildings. 20 Respondent argues in the alternative, however, that if an allocation is made by this Court, petitioners' calculation of the amount eligible for the credit based on consumption is incorrect because the proper way to measure the electrical distribution system is on the basis of electrical load which is measured in terms of kilovolt-amperes. In respondent's view, electrical load directly relates to the cost of all other components of the system and is the primary means of measuring the capacity of a system.
1986 Tax Ct. Memo LEXIS 481">*576 Respondent takes the view that the electrical distribution systems constitute structural components of petitioners' cafeterias within the meaning of
Respondent also disputes the allocation of the electrical distribution system between qualifying and nonqualifying uses1986 Tax Ct. Memo LEXIS 481">*577 of the electrical power. Respondent cites
1986 Tax Ct. Memo LEXIS 481">*578 Respondent argues that the electrical distribution system in the instant case was designed to meet the electrical requirements of the cafeteria as a whole rather than just the kitchen requirements and the location and routing of the electrical components were planned to meet electrical power requirements petitioners might have from any source. The components of the electrical distribution system, in respondent's view, were installed to be permanent and removal would render the cafeteria building useless. Respondent points out that the reasonable adaptability of the electrical distribution system with minimal effort to accommodate another cafeteria, a restaurant or a retail sales establishment such as a furniture store, indicates that the system relates to the overall operation or maintenance of the building rather than relating to the function of specific pieces of kitchen machinery or equipment. Respondent recognizes that his argument is contrary to our holding in
In
it is appropriate to break down the electrical load carried by the primary1986 Tax Ct. Memo LEXIS 481">*580 electric in the same way as that of the secondary electric--by the amount of load caused by each category of consumptive device, i.e., lighting, ventilation, air-conditioning, process machinery, etc. Thus, it is appropriate to allow an investment credit for the primary electric improvements in a manner similar to that used by respondent with respect to the secondary electric improvements, i.e., by reference to circuit diagrams and electrical loads. To the extent that the primary electric carried electrical loads to be used for pulp and paper production processes or other such qualifying uses, the investment credit will be allowed for the primary electric improvements.
To the extent that the primary electric improvements relate to the overall operation [or] maintenance of buildings, they are structural components of such buildings, and they do not qualify as tangible personal property. [
From the above it is clear that in
Footnotes
1. These deficienies result from disallowance of net operating loss carrybacks.↩
2. Unless otherwise stated, all statutory references are to the Internal Revenue Code of 1954, as amended and in effect during the years here in issue. ↩
3. After the parties reached an agreement on the eligibility of certain items with respect to which the investment credit was disallowed in the notices of deficiency, the credit with respect to the following items with the indicated expenditure remain in issue:
Item Expenditure 1. Emergency lighting $95,967 2. Kitchen panel boards 116,850 3. Kitchen hand sinks 21,392 4. Kitchen water piping 189,214 5. Eliason doors 15,930 6. Restroom accessories 54,240 7. Decor window treatment 3,713 8. Lattice millwork 2,134 9. Vanity cabinets and counters 1,931 10. Customer line screen 111,422 11. Serving line concrete curb 12,406 12. Kitchen heat recovery unit 23,859 13. Cooler, freezer and garbage room floors and the garbage room 149,094 14. Kitchen sanitary wall and floor tile 919,557 15. Kitchen air makeup unit 473,560 16. Kitchen drainage 364,977 17. Electric water coolers 15,287 18. Chandeliers, decor wall lights, dimmers and installation 178,871 19. Kitchen hot water heater 60,734 20. Primary electrical distribution system *↩ 699,884Petitioners filed claims for refunds for their expenditures for the primary electrical distribution systems in the total amount of $699,884. The refund claimed is 10 percent of this amount or $69,988.40.
4. These corporations and their State of incorporation are as follows:
↩ Name State of Incorporation Morrison Inc. Florida Morrison of Savannah Georgia Morrison of Woodland Hills Mississippi Morrison of Tennessee Tennessee Morrison Cafeteria Co., Inc. Alabama Morrison of Columbia, S.C. South Carolina Morrison of Jefferson Parish Louisiana Morrison Support Co. of Georgia Georgia Morco Industries Florida Morrison Food Services of Va. Virginia 5. Petitioners did not claim investment tax credit for their primary electrical distribution system on their tax returns, but some have filed claims for refund claiming investment tax credit on the primary electrical distribution system. The investment tax credit for the primary electrical distribution system as claimed by petitioners are for the years and in the amounts as follows:
↩ Name Year Ending Amount Morrison Incorporated May 28, 1977 $19,315 June 3, 1978 31,415 Morrison of Woodland Hills May 28, 1977 June 3, 1978 40 Morrison of Tennessee June 3, 1978 5,707 Morrison Cafeteria Co. June 3, 1978 2,771 Morrison of Columbia, S.C. June 3, 1978 6,458 Morrison of Jefferson Parish May 31, 1976 11,963 June 3, 1978 Morrison of Virginia May 28, 1977 2,639 June 3, 1978 Morrison of Savannah May 28, 1977 2,462 *. These figures differ from amounts in issue as stated on original stipulation because of elimination of amounts attributable to Goldsboro N.C. unit.↩
6. The percentages will change depending upon our determination of whether the kitchen air makeup unit qualifies for investment tax credit.↩
7. Respondent allowed the investment tax credit with respect to the circuit breakers and wires directly leading to these appliances.↩
8. See
. A credit was allowed inDuaine v. Commissioner, T.C. Memo. 1985-39Duaine for a restaurant's gas, plumbing and electrical fixtures that did not relate to general building services such as lighting, heating or ventilation. All the fixtures in issue directly serviced the taxpayer's equipment and machinery. Therein we also citedRev. Rul. 66-299, 2 C.B. 14">1966-2 C.B. 14 , 16, which specifically states that--special electrical or plumbing connections which are necessary to and are used directly with a specific item of machinery or equipment, or between specific items of individual, machinery or equipment, are not structural components of the building, but are essentially items of machinery or equipment, and qualify as section 38 property for investment credit purposes.↩
9. Respondent states that his position is supported by
, affd. per curiam without published opinion (8th Cir. 1985), andMallinckrodt, Inc. v. Commissioner, T.C. Memo. 1984-532Dixie Manor, Inc. v. United States, an unreported case (W.D. Ky. 1979, 47 AFTR 2d 81-1298, 79-2 USTC par. 9469), affd. without published opinion652 F.2d 57">652 F.2d 57 (6th Cir. 1981).In
Mallinckrodt, Inc, v. Commissioner, supra , we addressed whether gypsum drywall partitions used in office buildings qualified for the investment tax credit. The partitions divided the interior of the buildings into offices or utility space and were not capable of being removed or reused in their entirety or being stored as a unit. We concluded that the partitions were structural components due to their permanent nature. The facts in theMallinckrodt case are totally distinguishable from those in the instant case.In
Dixie Manor, the Court addressed whether four partitions installed by a music company occupying space in a shopping center qualified as section 38 property. One of the items was drywall on wood studs, and some walls had paneled wainscoting and others were full-ceiling height in the restrooms. The District Court concluded that the partitions constituted structural components due to their permanent manner of attachment and the fact that the partitions were not readily movable. The facts in theDixie Manor↩ case are also distinguishable from the facts in the instant case.10. Respondent cites
, to support his position that the concrete curb constitutes a structural component ineligible for the credit.Duaine v. Commissioner, T.C. Memo. 1985-39In
Duaine, the taxpayers claimed an investment tax credit for a portion of the Taco Bell restaurant's concrete foundation slab located behined the counter. We held inDuaine↩ that the underlying concrete foundation slab, although slightly modified for design considerations, was clearly a structural component of the building.11. Respondent relies on
, in which we held that wall and floor tiles in the taxpayer's restaurant food preparation, refrigeration, storage and loading areas constituted a permanent covering for the restaurant's walls and floors and hence constituted structural components ineligible for the investment tax credit.Duaine v. Commissioner, T.C. Memo. 1985-39↩12. Respondent cites
, in which this Court held that a cold storage room constructed to store ice in an ice manufacturing plant constituted a building and did not qualify for the credit.Circle K Corp. v. Commissioner, T.C. Memo. 1982-298In
Circle K. Corp., the taxpayer operated an ice manufacturing plant and constructed an addition which was a cold storage room. We held that the taxpayer was not entitled to the investment tax credit on this cold storage room because of its failure to prove that it was necessary to place the ice in a cold storage room for 24 hours in order to complete the manufacturing process. This proof was necessary to show that cold storage of the ice for a 24-hour period was an integral part of the manufacturing process as required insection 1.48-1(d)(4), Income Tax Regs.↩ 13. Respondent again cites
, to support his position. In that case we held that the wall and floor tiles in the food preparation, refrigeration, storage and loading areas of a restaurant constituted structural components of the building because the tiles are permanently glued to the restaurant's walls and floors.Duaine v. Commissioner, T.C. Memo. 1985-39↩14. See
Rev. Rul. 81-240, 2 C.B. 11">1981-2 C.B. 11 ;Rev. Rul. 75-77, 1 C.B. 7">1975-1 C.B. 7↩ .15. Respondent attempts to distinguish
, in which we held the connectors between the taxpayer's restaurant equipment and the drainage system to be tangible personal property. The drainage system itself was not at issue inDuaine v. Commissioner, T.C. Memo. 1985-39Duaine. InDuaine, the taxpayers claimed an investment tax credit for the plumbing and gas fixtures connecting the Taco Bell restaurant equipment to incoming utility "stub-outs," electrical outlets and conduit providing localized power sources for their equipment, the drain line connecting the taxpayers' refrigerators and sinks to the building drains, and the water lines providing water from the water mains to steam trays, cooking vessels and ice machines. InDuaine, we applied the test from (1980), and concluded that the restaurant's gas, plumbing and electrical fixtures did not relate to general building services such as lighting, heating and ventilation, which involved the operation or maintenance of a building but to the operation of the taxpayers' equipment and machinery. Respondent attempts to distinguishScott Paper Co. v. Commissioner, 74 T.C. 137">74 T.C. 137Duaine on the ground that the drainage system itself was not at issue in that case. We do not agree with respondent that theDuaine↩ case is distinguishable from the instant case with respect to the drains.16. See
Rev. Rul. 66-299, 2 C.B. 14">1966-2 C.B. 14↩ .17. Respondent also relies on
, in which the taxpayer claimed an investment tax credit for the interior and exterior ornamental light fixtures of the Taco Bell restaurant. We held inDuaine v. Commissioner, T.C. Memo 1985-39">T.C. Memo 1985-39Duaine↩ that the taxpayer's contention that the ornamental lighting fixtures were purely decorative was not supported by the record and we concluded that the interior and exterior lighting fixtures provided the only artificial lumination in the customer easting area and along the walkways to the buildings. We held that the interior and exterior lighting fixtures constituted structural components of the restaurant and related to the operation or maintenance of the building housing the restaurant. We stated that the ability of the restaurant's designer to camouflage the standard lighting requirements by incorporating the restaurant's motif into their appearance did not warrant a contrary conclusion.18. In
, this Court held that chandeliers and hanging lanterns used in the taxpayer's restaurant did not relate to the operation or maintenance of the building but were designed specifically for decorative use in the restaurant and enhanced its atmosphere. The chandeliers could be removed from one location and shipped to another if needed. Removal did not damage the chandeliers or lanterns. They were replaced on the average of every 5 to 7 years either in connection with general remodeling or with installation of new salad or breakfast bars. After applying the permanency test ofShoney's South, Inc. v. Commissioner, T.C. Memo. 1984-413 , 65 T.C. 664">672-673 (1975), we concluded that the chandeliers and lanterns were not reasonably permanent and that they were assets accessory to the taxpayer's business, S. Rept. 1881, 87th Cong., 2d Sess. (1962),Whiteco. Industries, Inc. v. Commissioner, 65 T.C. 664">65 T.C. 6643 C.B. 707">1962-3 C.B. 707 , 722, rather than components relating to the operation or maintenance of the building in which they were located. Petitioners' chandeliers and decor wall lights serve the same function as those inShoney's South.↩ 19. Petitioners add that if we determine that the kitchen panel boards are eligible for the credit, then the cost attributable to the kitchen panel boards will be subtracted from the cost of the secondary electric before the 69.2 percent is applied.↩
20. Respondent did not disallow the credit claimed in the tax returns for the part of the electrical distribution system that connects directly to petitioners' kitchen machinery and equipment. This includes the cost of the wiring, conduit and circuit breakers by which the machinery and equipment is actually connected to the electrical distribution system.↩
21. Respondent states on brief that if an allocation is made, a credit should only be allowed for the primary electric because it serves a dual function--the operation or maintenance of the building and the operation of the machinery and equipment.↩
22. The Fourth Circuit in
(4th Cir. 1982), held that the proper approach is to determine whether the electrical system has more general uses than special uses for operating items of machinery and, if so, the system is a structural component of the business and hence nonqualifying. Any appeal in this case will lie in the Eleventh Circuit, so we need not reexamine our holding in theA.C. Monk & Co. v. United States, 686 F.2d 1058">686 F.2d 1058Scott Paper Co.↩ case at this time.