259 Pa. 389 | Pa. | 1918
Opinion by
This is an action by parents to recover damages for the death of an adult son. There is a line of poles in the Butler Pike in Allegheny County, used jointly by defendant and the Bell Telephone Company. One of said poles is located opposite the residence of a Mr. DeHaven and has three cross-arms; the lowest is used by the telephone company, the top by defendant for its high tension wires, and the middle, known as the buck-arm, is used by defendant for house wires. The transformer is contained in a metal case suspended from the upper cross-arm by iron hooks and comes down to within about four inches of the buck-arm. Its purpose is to reduce the current from 2,200 to 110 volts. The telephone company’s messenger wire extends from the pole and is attached to it near the lowest cross-arm. It is considered a grounded wire, as is also an uninsulated guy wire fastened to the pole below the transformer. Plaintiff’s son, Louis P. Paulk, was in defendant’s employ as a lineman, and, on October 5, 1914, was directed by the foreman, who was in reality a vice-principal, to permanently connect some wires at or near the transformer. Young Paulk climbed the pole for that purpose and was immediately killed by an electric shock. No one saw the ac-. cident. Mr. Ford, a fellow lineman, was about fifty feet away, and, attracted by the noise, turned and saw Paulk in an upright position on the pole, and called twice to him but received no response. Ford then climbed the pole and found the deceased with his arms and safety
Defendant concedes that the question of its negligence was for the jury, but urges that the trial court erred in failing to hold that the deceased was guilty of contributory negligence. Defendant offered oral evidence, not controverted, to the effect that Faulk had been instructed as to the dangers of the business and warned not to touch a transformer case or messenger wire. However, he had not been warned of the defective condition of this transformer. He was sent to work in immediate proximity to high tension wires and a live metal case, with grounded wires near where he was required to stand, which made the place one of great danger. Under such circumstances the happening of the accident itself does not convict him of negligence. Careful and competent men are killed while working around live wires. No one knows just how the accident happened. The deceased is presumed to have used care. True, he was found with his foot on the messenger wire and it would seem that his arm had touched the transformer case; but it does not clearly appear that either act was done intentionally or negligently. A slight slip or misstep might easily have caused the accident. Both feet were burned while only one was found on the messenger wire, and this may have been by an involuntary movement after the shock. The
The assignments of error are overruled and the judgment is affirmed.