10 Pa. Commw. 15 | Pa. Commw. Ct. | 1973
Opinion and Order by
The Buckeye Coal Company (“Company”) has appealed to this court from the decision of a commission appointed by the Secretary of the Department of Environmental Resources to examine into the matter of an appealed decision of a district mine inspector. The governing statute is the Pennsylvania Bituminous Coal Mine Act, Act of July 17,1961, P. L. 659, 52 P.S. §701-101 et seq., Section 123 of which (52 P.S. §701-123) describes the procedures before our court as follows: “The mine inspector shall exercise sound discretion in the performance of his duties under the provisions of this act, and if the operator, superintendent, mine foreman, or other person employed in or about any mine, shall be dissatisfied with any decision the mine inspector has given in the discharge of his duties, which decision shall be in writing, it shall be the duty of the dissatisfied person to appeal from said decision to the secretary, who shall at once appoint a commission to accompany promptly the mine inspector in the district
While our jurisdiction is not a specific issue raised by either party, it is involved. We are advised that Company, as a precaution, has also filed an appeal pursuant to Section 123, supra, in the Court of Common Pleas of Greene County. Jurisdiction is in this Court, not the Court of Common Pleas of Greene County. Section 123 was repealed by the Appellate Court Jurisdiction Act of 1970 insofar as it vests jurisdiction and powers in courts in any matter inconsistent therewith. Act of July 31, 1970, P. L. 673, §509 (g) (55), added by Act of June 3,1971, P. L. , 17 P.S. §211.509 (g) (55). In Hartman v. Commonwealth, 6 Pa. Commonwealth Ct. 409, 295 A. 2d 850 (1972), we held that provisions of The Vehicle Code identical to Section 123
Having thus determined that ive had jurisdiction, we received the evidence proffered by the parties in extensive hearings. After review of such testimony as has been transcribed, our notes as to the rest and oral argument, we make the following:
Findings of Fact
(1) The Buckeye Coal Company, (“Company”), a subsidiary of Youngstown Sheet and Tube Company, is the owner and operator of a bituminous coal mine located in Greene County and known as the Nemacolin Mine.
(2) The Nemacolin mine is located within the so-called Pittsburgh seam, a rich deposit of bituminous coal stretching almost uninterruptedly from Charleston, West Virginia to Windber Borough, near the northern boundary of Somerset County, Pennsylvania.
(3) At the Nemacolin mine the Pittsburgh seam is about 400 feet below the surface of the land. The Nemacolin mine is a so-called shaft mine, that is, one in which the coal is reached by shafts dug to the level of the seam, although in the case of Nemacolin there is at least one point at which there is an opening at the surface through which access can be had by foot over a slope to the workings.
(4) The Nemacolin mine is bounded on one side by the Monongahela River and the coal seam is below the level of the river. As a result of this and other factors, the earth at the level of the coal seam of the Nemacolin mine has been saturated with water for eons.
(5) The Pittsburgh seam is about eight feet thick. It is mined at Nemacolin by driving corridors through the seam. These corridors are variously called entries,
(6) The process of driving the entries and the crosscuts is called development of the mine. Alter the development of a portion of the mine is completed the pillars of coal are removed commencing at a place farthest from the entrance. This process is called retreating.
(7) The entries and crosscuts are about 17 feet wide. At the right angle intersections of entries and crosscuts, the diagonal dimension of the open spaces are about 24 feet.
(8) The entries and crosscuts are about seven feet high. This height provides a roof of coal about one foot thick for the entries and crosscuts.
(9) Above the said roof of coal in the Nemacolin mine, there are layers of slate, shale and so-called rooster coal of a total thickness of four or five feet. Above this fractured material is a bed of sandstone as much as 50 feet thick.
(10) The stratum of sandstone in the Nemacolin mine is massive and competent. A competent rock is one capable of supporting that which is above it.
(11) Roof support, in addition to that provided by the coal pillars in the Nemacolin mine, is prescribed by a Roof Support Plan approved by the United States Department of the Interior, Bureau of Mines, and the Department of Environmental Resources.
(12) The approved roof plan of the Nemacolin mine authorizes the use of roof bolts as a means of roof support.
(14) The roof bolt is also passed through a wooden header block and a steel plate which are placed against the mine roof. By tightening of the bolt, the block and plate are pressed against the roof and held there by the bolt anchored in the sandstone above. One witness accurately described roof bolting as the nailing of a ceiling to rafters.
(15) In the Nemacolin mine the bolts are placed four feet apart longitudinally and transversely.
(16) The Nemacolin roof plan provides for other means of roof support where roof bolts cannot be used, that is, where the bolts cannot be adequately anchored in the sandstone. These other means of support are “cross timbering,” which consists of posts on either side of the corridor on the top of which are affixed timbers against the roof, and “center-posting,” which is the placement of posts in the middle of the entries or crosscuts.
(17) The roof of the Nemacolin mine is less subject to falls than roofs of 60 per cent of the mines in the Pittsburgh seam.
(18) The holding quality of roof bolts is determined by taking tests, by means of torque wrenches, which measure the amount of pressure necessary to turn the bolt. If the bolt turns too easily the indication is that it is not supporting the roof and is therefore not anchored in a sufficient beam; if too much energy is necessary to turn the bolt the indication is that there is excessive weight on the bolt.
(20) The Nemacolin mine is divided into sections which are given names. One such section, called the 118 Road Section, consists of seven entries numbered 1 through 7, and of fifteen crosscuts numbered 1 through 15.
(21) In March 1971, a fire broke out in the 118 Road Section of the Nemacolin mine. Efforts were made to fight the fire underground and by the introduction of slag until sometime in April, 1971 when it was determined that the only way to extinguish the fire was by flooding. Bulkheads were constructed for this purpose and the mine flooded to depth which immersed the entries, the crosscuts and the overburden, including the shale above the roof.
(22) The flooding was completed in September 1971 and the mine remained flooded until about September 1972.
(23) Between March of 1971 and September 1972, the Company engaged in cutting through the coal in other sections in the direction of the 118 Road Section, which was reached on September 14, 1972. Thereupon a mine rescue team explored the 118 Road Section and a map was made by persons on the surface by recording on a plan of the mine observations transmitted by telephone from below.
(24) The observations of the mine rescue team included descriptions of roof conditions as being good in many places in the 118 Road Section.
(25) The work of inspection continued until the bodies of the two victims of the fire were brought out in September or October 1972.
(26) After the inspection of the mine in September and October of 1972, the Company decided that it would
(27) In addition, the Company proposes to use as an airway and alternate escape route, a succession of entries and crosscuts connecting with entry 4 and extending to a bulkhead numbered 15, to be referred to hereafter as the extension.
(28) Such use of the three entries Avould, during the period of recovery of equipment, require the use of trackage presently located in entries 2 and 4. The provision of ventilation Avould also require the construction of air stoppings in the vicinity, necessitating the use of the tracks. It is estimated by the Company that the period of time during which the tracks would be used for the purpose of removing machinery and equipment and constructing stoppings would be about four months, after which, except for required weekly inspections of the three entries by one person, the 118 Road Section would not be used.
(29) The district mine inspector, in concert Avith the Director of the Bureau of Deep Mine Safety of the Department of Environmental Resources, after some rehabilitation Avork had been done in the 118 Road Section, decided that the Company could not use any of the Section Avithout cross timbering the whole.
(30) On appeal from the inspector’s order a commission consisting of State inspectors from other districts visited the mine once and ordered that the two entries in which tracks were located and Avere to be
(31) The Company, believing that much of the roof in the section was adequately supported by roof bolts, appealed the Commission order to this Court.
(32) The area of most intense fire is located about 500 or 600 feet from entries 2, 4 or 6 and about 2000 feet from the facings of 118 Road Section.
(33) About 400 torque tests were taken by the Federal Bureau of Mines and the same number by the Commission in entries 2, 4 and 6 and those indicated that the roof was adequately supported in most areas.
(34) The Federal Bureau made pull tests on seven bolts and these were properly anchored.
(35) The Federal Bureau and some of the Company’s experts made stratascope observations of the materials in the roof and observed no deterioration of the shale, slate, roof coal, sandstone or other materials.
(36) Tensile strength tests made by the Federal Bureau and the Company proved that the bolts and metal plates were unaffected by fire or water.
(37) The existing roof bolts offer adequate roof support in mast of the areas of 2, 4 and 6 entries.
(38) The coal forming the roof of the entries was not affected by water.
(39) The roof bolts were not weakened by water.
(40) The slate, shale, rooster coal and other materials overlying the roof of entries 2, 4 and 6 were not so affected by fire or water as to increase the danger of falls.
(41) The Company’s plan provides adequate additional roof support in those areas of entries 2, 4 and 6 where by reason of fire the roof has fallen or otherwise been affected.
(43) The extension of entry 4 to bulkhead 15 shown on Exhibit P-3 has not been inspected by the Federal Bureau of Mines or any other official body and has been examined only by the mine foreman and assistant superintendent.
(44) The areas where men work the Nemacolin mine are inspected daily by foreman and fire bosses. A representative of the Federal Bureau of Mines is present at the mine some part of every day. State Inspectors make regular visitations and are on immediate call. The union safety committee can close portions of the mine temporarily as can any individual miner simply by posting “danger” signs at the affected area.
(45) The Commission’s order went beyond the necessities of the case and will greatly and unnecessarily delay the provision of additional ventilation and escape ways, not required, but desired to be provided for the increased safety of persons working in the Nemacolin mine.
(46) The Company’s plan for roof support suggested by its Exhibit 3 provides adequately for the support of roofs of entries 2, 4 and 6 to crosscut 15.
Discussion
The State mine inspector assigned to the Nemacolin mine decided that the areas of 118 Road Section “where men are travelling” should be cross timbered on four foot centers. The commission, consisting of three other mine inspectors which conceived its function to be “To conduct a complete and accurate investigation of
“1. That all areas where men will work and travel as haulageways shall be timbered as requested by the District Mine Inspector.
“2. That return areaways where mandatory examination required by law will be made, shall be center-posted on at least four foot centers.”
By Section 123, supra, we are told to “promptly hear such appeal, and [to] permit testimony and argument, oral or written, or both, by both parties. In such appeal, the appellant shall be designated the plaintiff and the secretary shall be the defendant. Within five days after conclusion of testimony and argument, the said court shall issue such decision and order as may be proper and appropriate under the circumstances.” It is clear that what is contemplated by that provision is a de novo hearing and that the court shall determine the facts and make such order as it deems proper based upon the record. This is particularly evident, since unlike similar appeal provisions of The Vehicle Code,
There is, therefore, no issue as to the burden of proof. We are to make our own determination from the evidence of what kind and amount of roof support is needed to assure the safety of persons who may enter the mine, considering all of the circumstances, including the use to be made of the areas in question.
Section 123, supra, provides further that the appellant shall be designated the plaintiff and the secretary the defendant. If this provision has significance beyond that of prescribing the caption, it is that the appellant shall have the burden of going forward with the evidence. We discern an analogy in Section 517 of the Eminent Domain Code
We have carefully considered the evidence and have concluded that the Company's proposal provides better provision for roof support of the areas affected by fire and water than the Commission’s. Our conclusion is based upon the following considerations, not listed in order of their importance to our decision:
1. Representatives of the Federal Bureau of Mines performed torque tests of 10% of the bolts in entries 2, 4 and 6 of the 118 Road Section, made pull tests on seven bolts at different locations and made tensile strength tests on bolts taken from the mine. The inspector concluded: “The evaluation indicates that the roof bolts offer adequate roof support in most areas.” The torque readings were submitted to the Commission but seemingly given little or no attention by it. The Bureau took over 400 readings. The Commission seems to have taken about 30, and many of these were within acceptable limits.
2. The Company also made about 400 torque tests, the vast majority of which were satisfactory.
3. The Company, as well as the Federal authorities, made tensile strength tests on bolts taken from the mine and these showed no deterioration. The Commission made no such tests but makes much in its report of the corrosive effect of fire, heat and water on the bolts. It concluded that “galvanic action” would also cause corrosion and weakening of the bolts. Its own expert agreed that galvanic action, if present, would be in such meager amount as to have no effect.
4. Eminently qualified professional engineers possessing baccalaureate and graduate degrees from the
5. The Company has no intention of using the 118 Road Section in mining operations. As we have found, it intends to use tracks in entry 4 and possibly entry 2
6. There are bad sections of roof at 12 and 13 crosscuts of entries 2, 3 and 4. When at argument it was pointed out that the Company would be greatly delayed in reaching and repairing these areas by the requirement of cross timbering, the Department’s counsel suggested that we might modify the Commission’s order to permit this work to be done, with the cross timbering of the intervening places to follow later. If the existing roof bolting is adequate support for this purpose, the Department’s insistence that it must be supplemented by cross timbering for the short time necessary to remove machinery and equipment and construct stoppings is somewhat difficult to understand.
7. The mine is under constant surveillance, inspection and subject to immediate regulation in the interests of safety. As we have found, working areas are
8. The areas of roof which are supported only by bolts in entries 2, 4 and 6 and which are the subject of this inquiry have stood since the fire in March 1971 and dewatering in September 1972 without falls or deterioration, except possibly for a small area showing deterioration in entry 6 between 8 and 10 crosscuts not shown on the Company’s plan as needing additional support. Between September 1972 and March 1, 1973, the date of the Commission’s order, many persons have traversed entries 2, 4 and 6 in the course of inspections and in the performance of rehabilitation work done before the mine inspector ordered cross timbering throughout. Since January 9, 1973, the date of the inspector’s order, many persons, including mine foremen and superintendents, prospective witnesses, lawyers, inspectors and mine safety committees, have repeatedly visited the areas.
9. The area of most intense fire as observed in March 1971 is located 500 or 600 feet from the nearest point of entries 2 and 4, intended for temporary use as haulageways for men removing equipment and erecting stoppings. The face of the 118 Road Section is about 2000 feet distant from the area of intense fire in March 1971. Articles taken from the entries show no evidence of fire. Where there is evidence of fire, in entries 2 and 4 at crosscuts 10 through 14, the Company proposes to cross timber.
"....
“Nine roof bolts and bearing plates were removed from several different locations ... to determine tensile strength of the roof bolts and make deflection tests on the bearing plates. . . .
"....
“The torque was checked on approximately 10 per cent of the roof bolts in the three entries. . . .
"....
“A stratascope was used to observe the strata in five of the holes from which the bolts had been removed and the strata appeared to be normal in all the holes.
"....
“Pull tests were made on seven roof bolts at different locations in the section to determine the anchorage strength of the strata.
“The evaluation indicates that the roof bolts offer adequate roof support in most areas.” Hence, positive tests could be and were made, not only by the Bureau of Mines but by the Company. They cannot be brushed aside in favor of unrecorded visual observations.
In sum, the record clearly establishes by scientific testing, by a vast preponderance of expert professional opinion, and by demonstrative evidence that, as the Federal Bureau’s inspector declares, “the roof bolts offer adequate support in most areas.”
We cannot leave our discussion without referring to the Department’s procedures in this matter. The superior of the mine inspector who originally ordered cross timbering throughout the section is the Department’s Director of the Bureau of Deep Mine Safety. The inspector clearly and properly consulted with the Director before making his order. When this order was appealed the Secretary appointed as a commission three mine inspectors from other districts of Pennsylvania, again persons supervised by the Director. At the hearings in our court the Director was obviously the head of the lay group supporting the Department’s case. Section 123, it seems to this writer, intends that the Commission appointed by the Secretary should make an independent judgment of the inspector’s requirements. Without intending in any way to reflect adversely upon the integrity of the members of this Commission, we find it impossible to believe that these gentlemen could make a critical judgment of a fellow inspector’s order concurred in by the head of the Bureau in which they were all employed. Surely there are professional engineers, knowledgeable lawyers, retired miners, retired operators and others in the State qualified to review an inspector’s order and give a truly independent report. We note further that the Commission’s report
We make the following:
Order
And Now, to wit, this 7th day of June, 1973, it is Ordered that the Commission’s report be and it hereby is set aside.
It is further Ordered that the Company’s plan for additional roof support shown on its Exhibit 3 be and it is hereby approved and ordered to be effected; provided, however, that posting on four foot centers shall be provided in entry 6 between crosscuts 8 and 10; and provided further that our approval of the Company’s plan for roof support in the extension of entry 4 from the intersection of entry 4 and crosscut 13 to bulkhead 15 is conditioned upon the taking of torque readings (if possible, by the Federal Bureau of Mines) of 10 per cent of the roof bolts in areas not proposed by the plan to be provided with supplementary support and if the results show that a majority of the roof bolts are not maintaining at least 70 per cent of the minimum torque required (50 per cent if plates bear against wood), or
It is further ordered that if the Company proposes work in the 118 Road Mains Left Section, included within the fire and inundation area as delineated by Commissioner Muchnok on Exhibit P-2 but not indicated on Exhibit P-3, the bolts in such working areas shall be tested as hereinabove required for the extension of entry 4 to bulkhead 15 and subject to the same standard of adequacy and supplementary support.
The Prothonotary is directed to enter this Order and give notice thereof to the parties of record and their counsel forthwith. If no exceptions thereto are filed within thirty (30) days after notice hereof, a final order shall be entered as of course by the Prothonotary.
Opinion and Final Order.
The Commonwealth has filed exceptions to the findings and conclusions of the opinion accompanying the order of Rogers, J. made June 7, 1973. Thirty-eight exceptions are to findings of fact. While none of these have been formally withdrawn, only those relating to findings of fact numbered 32, 40 and 41 are pressed in the Commonwealth’s brief or at argument. Therefore, as to the exceptions to all other findings, we need only state that we have reviewed the record and find support therein for each.
Our finding No. 32 was that the area of most intense fire was located about 500 or 600 feet from entries 2, 4 and 6 and 2000 feet from the facings of the 118 Road Section. This finding is supported by exhibits upon which the distances referred to may be ascertained by scaling. The Commonwealth’s objection to this finding, expressed at argument, is that it implies that there were not fires in other places in the mine.
The two remaining findings, the exceptions to which are pressed by the Commonwealth in brief and argument, are 40 and 41. Finding No. 40 is that the slate, shale, rooster coal and other materials overlying the roof were not so affected by fire or water as to increase the danger of falls. This finding, the Commonwealth asserts, is inconsistent with the admitted fact that there were falls following the fire and flooding. The roof of the entries consists of coal about one foot in thickness. The shale and other materials referred to in finding No. 40 are above this roof of coal. The finding is not that the roof of coal was not affected but only that the overlying materials were not so affected, except, of course, where the roof collapsed and the materials came down. Stratascope readings in the record clearly support this finding.
Finding No. 41 is as follows: “The Company’s plan provides adequate additional roof support in those areas of entries 2, 4 and 6 where by reason of fire the roof has fallen or otherwise been affected.” The Commonwealth contends that this finding is erroneous in view of undisputed testimony that there are places in the 118 Road Section where there is evidence of bad roof which are not proposed to be supplied with additional support by the company’s plan as solely indicated by Exhibit P-3. P-3 is a map of the mine on which the company has indicated areas where it has already supplied additional support and where it proposes to supply additional support. The Commonwealth insists that Exhibit P-3 is the company’s plan or proposal of roof support in its entirety. However, the company’s plan, in the sense of a proposal, as repeatedly testified to by its witnesses, is that it will certainly provide the
At argument the Commonwealth referred to three areas, one each in entry 4, entry 2 and entry 6, where additional support was assertedly needed but not shown on Exhibit P-3. The deteriorated area in entry 4 was alleged at argument to be between crosscuts 10 and 11. We have examined the record at page 431 and have ascertained that the admitted fault referred to at that place was at crosscuts 3 and 4, at which location Exhibit P-3 shows cross-timbering has already been accomplished. Our examination of the record discloses no location in entry No. 2 which is admittedly deteriorated and not proposed to receive supplemental support. Indeed, the company proposes to give additional support for all but a small portion of that entry.
As Judge Rogers mentions in the opinion, all of the notes of testimony had not been transcribed at the time his order was required to be made by the statute. Among the notes not so transcribed were those of the testimony of William Hanley, the assistant mine superintendent, commencing at page 1041. There Mr. Hanley on direct examination stated that there were places in the No. 6 entry where needed supplementary support must and would be supplied not so shown on Exhibit P-3. These areas are between crosscuts 10 and 11, and between crosscuts 8 and 9. Judge Rogers’ nisi order directs posting between crosscuts 8 and 11. Our final order will direct posting in accordance with the record between 8 and 9 and 10 and 11.
The company’s plan, in the sense of a proposal, includes additional supports at any area of the 118 Road Section which subsequently proves to need it. There
The Commonwealth has also taken serious exception to that portion of Judge Rogers’ opinion as suggests that the makeup of the commission might have been other than that of other mine inspectors. The Commonwealth reads the Pennsylvania Bituminous Coal Mine Act to require that all commissions should consist of mine inspectors and points to the definition of “investigating commission” at Section 103(16), 52 P.S. §701-103(16). However, an investigating commission is by the same section described as being “for the purpose of investigating and reporting on any problem.” Further, Section 124, 52 P.S. §701-124, empowers the secretary to appoint a commission “for the purpose of investigating any question ... to enable him to make a decision .. ..” The commission contemplated by Section 123, 52 P.S. §701-123, is not one which investigates in order to enable the secretary to make a decision. The commission makes the decision. It is, therefore, arguable that a Section 123 committee need not be composed entirely of mine inspectors. Nevertheless, the practice appears to have been in Section 123 cases always to appoint mine inspectors, and administrative interpretations of statutes as evidenced by long standing practice are entitled to weight. P.L.E., Statutes, Yol. 34, §155. In any event, Judge Rogers’ references
Finally, the Commonwealth excepts to that portion of Judge Rogues’ order regarding the taking of torque tests in areas in which the commission never traveled, and as to which there is very little testimony as to actual conditions. The Commonwealth argues that the order should have required that supplementary support should be provided wherever a majority of the readings exceeded the maximum torque of 240 or a minimum of 100 or 70 pounds, the latter two depending upon the presence or absence of wooden header blocks, these being the standards for the installation of bolts by the approved plan and state regulations. Judge Rogues’ order requiring supplementary support only if a majority of bolts are not maintaining at least 70% of the required minimum torque (50% if plates bear on wood) or exceeding the maximum by 50% is based upon Federal standards applicable in this situation. The order’s requirement is a precondition to any use of the areas and is in addition to all other requirements, including the inspections, hereinbefore mentioned, and the continued strict application of the company’s approved roof plan. It is not the establishment of a new plan but the imposition of a safety requirement in addition to all others and one not a part of the company’s proposal otherwise approved. We are not impelled to change the order in this respect.
We therefore make the following:
Final Ordue
And now this 9th day of August 1973, it is Ordered that the Commonwealth’s exceptions to the order of
It is further Ordered that the Company’s plan for additional roof support shown on its Exhibit 3 be and it is hereby approved and ordered to be effected; provided, however, that posting on four foot centers shall be provided in entry 6 between crosscuts 8 and 9 and 10 and 11; and provided further that our approval of the Company’s plan for roof support in the attention of entry 4 from the intersection of entry 4 and crosscut 13 to bulkhead 15 is conditioned upon the taking of torque readings (if possible, by the Federal Bureau of Mines) of 10 per cent of the roof bolts in areas not proposed by the plan to be provided with supplementary support and if the results show that a majority of the roof bolts are not maintaining at least 70 per cent of the minimum torque required (50 per cent if plates bear against wood), or have exceeded the maximum required torque by 50 per cent, supplementary support by posting on four foot centers shall be installed throughout the extension.
It is further ordered that if the Company proposes work in the 118 Eoad Mains Left Section, included within the fire and inundation area as delineated by Commissioner Muchnok on Exhibit P-2 but not indicated on Exhibit P-3, the bolts in such working areas shall be tested as hereinabove required for the extension of entry 4 to bulkhead 15 and subject to the same standard of adequacy and supplementary support.
Act of April 29, 1959, P. L. 58, §620, as amended, 75 P.S. §620.
Act of April 12, 1951, P. L. 90, §471, as amended, 47 P.S. §4-471.
For example, The Fourth to Eighth Class County Assessment Law, Act of May 21, 1943, P. L. 571, §§702, 704, as amended, 72 P.S. §§5453.702, 5453.704.
Act of June 4, 1945, P. L. 1388, §44, 71 P.S. §1710.44.
Act of June 22, 1964, Special Session, P. L. 84, §517, 26 P.S. §1-517.
The Company effectively rebutted this testimony by a witness with wide practical experience in both countries who declared that Indian miners lack the skill to place the bolts and that English mining methods are such as exclude the utility of roof bolting.